Digital Addressable Lighting Interface (DALI) is a trademark for network-based products that control lighting. The underlying technology was established by a consortium of lighting equipment manufacturers as a successor for 1-10 V/0–10 V lighting control systems, and as an open standard alternative to several proprietary protocols. The DALI, DALI-2 and D4i trademarks are owned by the lighting industry alliance, DiiA (Digital Illumination Interface Alliance).
DALI is specified by a series of technical standards in IEC 62386. Standards conformance ensures that equipment from different manufacturers will interoperate. The DALI trademark is allowed on devices that comply with the DiiA testing and certification requirements, and are listed as either registered (DALI version-1) or certified (DALI-2) on the DiiA website. D4i certification - an extension of DALI-2 - was added by DiiA in November 2019.
Members of the AG DALI were allowed to use the DALI trademark until the DALI working party was dissolved on 30 March 2017, when trademark use was transferred to DiiA members. Since 9 June 2017, Digital Illumination Interface Alliance (DiiA) certifies DALI products. DiiA is a Partner Program of IEEE-ISTO.
A DALI network consists of at least one application controller and bus power supply (which may be built into any of the products) as well as input devices (e.g. sensors and push-buttons), control gear (e.g., electrical ballasts, LED drivers and dimmers) with DALI interfaces. Application controllers can control, configure or query each device by means of a bi-directional data exchange. Unlike DMX, multiple controllers can co-exist on the bus. The DALI protocol permits addressing devices individually, in groups or via broadcast. Scenes can be stored in the devices, for recall on an individual, group or broadcast basis. Groups and scenes are used to ensure simultaneous execution of level changes, since each packet requires about 25 ms - or 1.5 seconds if all 64 addresses were to change level.
Each device is assigned a unique short address between 0 and 63, making up to 64 devices possible in a basic system. Address assignment is performed over the bus using a "commissioning" protocol built into the DALI controller, usually after all hardware is installed, or successively as devices are added. The Device Address is commonly a LED driver with one or many LEDs sharing the same level. A DT6 driver is for single color temperature applications, a DT8 driver is used for CCT color tuning, or RGBWW multi color applications - for example a strip where all the "pixels" have the same color.
Data is transferred between devices by means of an asynchronous, half-duplex, serial protocol over a two-wire bus with a fixed data transfer rate of 1200 bit/s. Collision detection is used to allow multiple transmitters on the bus.
A single pair of wires comprises the bus used for communication on a DALI network. The network can be arranged in bus or star topology, or a combination of these. Each device on a DALI network can be addressed individually, unlike DSI and 0–10V devices. Consequently, DALI networks typically use fewer wires than DSI or 0–10V systems.
The bus is used for both signal and bus power. A power supply provides a current limited source of up to 250 mA at typically 16 V DC; each device may draw up to 2 mA unless bus-powered. While many devices are mains-powered (line-powered), low-power devices such as motion detectors may be powered directly from the DALI bus. Each device has a bridge rectifier on its input so it is polarity-insensitive. The bus is a wired-AND configuration where signals are sent by briefly shorting the bus to a low voltage level. (The power supply is required to tolerate this, limiting the current to 250 mA.)
Digital Addressable Lighting Interface
Digital Addressable Lighting Interface (DALI) is a trademark for network-based products that control lighting. The underlying technology was established by a consortium of lighting equipment manufacturers as a successor for 1-10 V/0–10 V lighting control systems, and as an open standard alternative to several proprietary protocols. The DALI, DALI-2 and D4i trademarks are owned by the lighting industry alliance, DiiA (Digital Illumination Interface Alliance).
DALI is specified by a series of technical standards in IEC 62386. Standards conformance ensures that equipment from different manufacturers will interoperate. The DALI trademark is allowed on devices that comply with the DiiA testing and certification requirements, and are listed as either registered (DALI version-1) or certified (DALI-2) on the DiiA website. D4i certification - an extension of DALI-2 - was added by DiiA in November 2019.
Members of the AG DALI were allowed to use the DALI trademark until the DALI working party was dissolved on 30 March 2017, when trademark use was transferred to DiiA members. Since 9 June 2017, Digital Illumination Interface Alliance (DiiA) certifies DALI products. DiiA is a Partner Program of IEEE-ISTO.
A DALI network consists of at least one application controller and bus power supply (which may be built into any of the products) as well as input devices (e.g. sensors and push-buttons), control gear (e.g., electrical ballasts, LED drivers and dimmers) with DALI interfaces. Application controllers can control, configure or query each device by means of a bi-directional data exchange. Unlike DMX, multiple controllers can co-exist on the bus. The DALI protocol permits addressing devices individually, in groups or via broadcast. Scenes can be stored in the devices, for recall on an individual, group or broadcast basis. Groups and scenes are used to ensure simultaneous execution of level changes, since each packet requires about 25 ms - or 1.5 seconds if all 64 addresses were to change level.
Each device is assigned a unique short address between 0 and 63, making up to 64 devices possible in a basic system. Address assignment is performed over the bus using a "commissioning" protocol built into the DALI controller, usually after all hardware is installed, or successively as devices are added. The Device Address is commonly a LED driver with one or many LEDs sharing the same level. A DT6 driver is for single color temperature applications, a DT8 driver is used for CCT color tuning, or RGBWW multi color applications - for example a strip where all the "pixels" have the same color.
Data is transferred between devices by means of an asynchronous, half-duplex, serial protocol over a two-wire bus with a fixed data transfer rate of 1200 bit/s. Collision detection is used to allow multiple transmitters on the bus.
A single pair of wires comprises the bus used for communication on a DALI network. The network can be arranged in bus or star topology, or a combination of these. Each device on a DALI network can be addressed individually, unlike DSI and 0–10V devices. Consequently, DALI networks typically use fewer wires than DSI or 0–10V systems.
The bus is used for both signal and bus power. A power supply provides a current limited source of up to 250 mA at typically 16 V DC; each device may draw up to 2 mA unless bus-powered. While many devices are mains-powered (line-powered), low-power devices such as motion detectors may be powered directly from the DALI bus. Each device has a bridge rectifier on its input so it is polarity-insensitive. The bus is a wired-AND configuration where signals are sent by briefly shorting the bus to a low voltage level. (The power supply is required to tolerate this, limiting the current to 250 mA.)