Recent from talks
Knowledge base stats:
Talk channels stats:
Members stats:
Fujita scale
The Fujita scale (F-Scale; /fuˈdʒiːtə/), or Fujita–Pearson scale (FPP scale), is a scale for rating tornado intensity, based primarily on the damage tornadoes inflict on human-built structures and vegetation. The official Fujita scale category is determined by meteorologists and engineers after a ground or aerial damage survey, or both; and depending on the circumstances, ground-swirl patterns (cycloidal marks), weather radar data, witness testimonies, media reports and damage imagery, as well as photogrammetry or videogrammetry if motion picture recording is available. The Fujita scale, named for the meteorologist Ted Fujita, was replaced with the Enhanced Fujita scale (EF-Scale) in the United States in February 2007. In April 2013, Canada adopted the EF-Scale over the Fujita scale along with 31 "Specific Damage Indicators" used by Environment Canada (EC) in their ratings.
The scale was introduced in 1971 by Ted Fujita of the University of Chicago, in collaboration with Allen Pearson, head of the National Severe Storms Forecast Center/NSSFC (currently the Storm Prediction Center/SPC). The scale was updated in 1973, taking into account path length and width. In the United States, starting in the late 1970s, tornadoes were rated soon after occurrence. The Fujita scale was applied retroactively to tornadoes reported between 1950 and the adoption of the scale in the National Oceanic and Atmospheric Administration (NOAA) National Tornado Database. Fujita rated tornadoes from 1916 to 1992 and Tom Grazulis of The Tornado Project retroactively rated all known significant tornadoes (F2–F5 or causing a fatality) in the U.S. back to 1880. The Fujita scale was adopted in most areas outside of the United Kingdom.[citation needed]
On February 1, 2007, the Fujita scale was decommissioned, and the Enhanced Fujita Scale was introduced in the United States. The new scale more accurately matches wind speeds to the severity of damage caused by the tornado.
Though each damage level is associated with a wind speed, the Fujita scale is effectively a damage scale, and the wind speeds associated with the damage listed are not rigorously verified. The Enhanced Fujita Scale was formulated due to research that suggested that the wind speeds required to inflict damage by intense tornadoes on the Fujita scale are greatly overestimated. A process of expert elicitation with top engineers and meteorologists resulted in the EF scale wind speeds, but these are biased to United States construction practices. The EF scale also improved damage parameter descriptions.[citation needed]
The original scale as derived by Fujita was a theoretical 13-level scale (F0–F12) designed to smoothly connect the Beaufort scale and the Mach number scale. F1 corresponds to the twelfth level of the Beaufort scale, and F12 corresponds to Mach number 1.0. F0 was placed at a position specifying no damage (approximately the eighth level of the Beaufort scale), in analogy to how Beaufort's zeroth level specifies little to no wind. From these wind speed numbers, qualitative descriptions of damage were made for each category of the Fujita scale, and then these descriptions were used to classify tornadoes.
At the time Fujita derived the scale, little information was available on damage caused by wind, so the original scale presented little more than educated guesses at wind speed ranges for specific tiers of damage. Fujita intended that only F0–F5 be used in practice, as this covered all possible levels of damage to frame homes as well as the expected estimated bounds of wind speeds. He did, however, add a description for F6, which he called an "inconceivable tornado", to allow for wind speeds exceeding F5 and possible advancements in damage analysis that might show it.
Based on aerial photographs of the damage it caused, Fujita assigned the strongest tornado of the 1974 Super Outbreak, which affected Xenia, Ohio, a preliminary rating of F6 intensity ± 1 scale. The 1977 Birmingham–Smithfield F5 tornado's damage was surveyed by Ted Fujita and he "toyed with the idea of rating the Smithfield tornado an F6". In 2001, tornado expert Thomas P. Grazulis stated in his book F5–F6 Tornadoes; "In my opinion, if there ever was an F6 tornado caught on video, it was the Pampa, Texas tornado of 1995". In 2023, it was announced by the Storm Prediction Center and National Weather Service Norman, Oklahoma that the 1970 Lubbock tornado was originally rated F6, which was later downgraded to its official rating of F5.
Furthermore, the original wind speed numbers have since been found to be higher than the actual speeds required to incur the damage described at each category. The error manifests itself to an increasing degree as the category increases, especially in the range of F3 through F5. NOAA notes that "precise wind speed numbers are actually guesses and have never been scientifically verified. Different wind speeds may cause similar-looking damage from place to place—even from building to building. Without a thorough engineering analysis of tornado damage in any event, the actual wind speeds needed to cause that damage are unknown."
Hub AI
Fujita scale AI simulator
(@Fujita scale_simulator)
Fujita scale
The Fujita scale (F-Scale; /fuˈdʒiːtə/), or Fujita–Pearson scale (FPP scale), is a scale for rating tornado intensity, based primarily on the damage tornadoes inflict on human-built structures and vegetation. The official Fujita scale category is determined by meteorologists and engineers after a ground or aerial damage survey, or both; and depending on the circumstances, ground-swirl patterns (cycloidal marks), weather radar data, witness testimonies, media reports and damage imagery, as well as photogrammetry or videogrammetry if motion picture recording is available. The Fujita scale, named for the meteorologist Ted Fujita, was replaced with the Enhanced Fujita scale (EF-Scale) in the United States in February 2007. In April 2013, Canada adopted the EF-Scale over the Fujita scale along with 31 "Specific Damage Indicators" used by Environment Canada (EC) in their ratings.
The scale was introduced in 1971 by Ted Fujita of the University of Chicago, in collaboration with Allen Pearson, head of the National Severe Storms Forecast Center/NSSFC (currently the Storm Prediction Center/SPC). The scale was updated in 1973, taking into account path length and width. In the United States, starting in the late 1970s, tornadoes were rated soon after occurrence. The Fujita scale was applied retroactively to tornadoes reported between 1950 and the adoption of the scale in the National Oceanic and Atmospheric Administration (NOAA) National Tornado Database. Fujita rated tornadoes from 1916 to 1992 and Tom Grazulis of The Tornado Project retroactively rated all known significant tornadoes (F2–F5 or causing a fatality) in the U.S. back to 1880. The Fujita scale was adopted in most areas outside of the United Kingdom.[citation needed]
On February 1, 2007, the Fujita scale was decommissioned, and the Enhanced Fujita Scale was introduced in the United States. The new scale more accurately matches wind speeds to the severity of damage caused by the tornado.
Though each damage level is associated with a wind speed, the Fujita scale is effectively a damage scale, and the wind speeds associated with the damage listed are not rigorously verified. The Enhanced Fujita Scale was formulated due to research that suggested that the wind speeds required to inflict damage by intense tornadoes on the Fujita scale are greatly overestimated. A process of expert elicitation with top engineers and meteorologists resulted in the EF scale wind speeds, but these are biased to United States construction practices. The EF scale also improved damage parameter descriptions.[citation needed]
The original scale as derived by Fujita was a theoretical 13-level scale (F0–F12) designed to smoothly connect the Beaufort scale and the Mach number scale. F1 corresponds to the twelfth level of the Beaufort scale, and F12 corresponds to Mach number 1.0. F0 was placed at a position specifying no damage (approximately the eighth level of the Beaufort scale), in analogy to how Beaufort's zeroth level specifies little to no wind. From these wind speed numbers, qualitative descriptions of damage were made for each category of the Fujita scale, and then these descriptions were used to classify tornadoes.
At the time Fujita derived the scale, little information was available on damage caused by wind, so the original scale presented little more than educated guesses at wind speed ranges for specific tiers of damage. Fujita intended that only F0–F5 be used in practice, as this covered all possible levels of damage to frame homes as well as the expected estimated bounds of wind speeds. He did, however, add a description for F6, which he called an "inconceivable tornado", to allow for wind speeds exceeding F5 and possible advancements in damage analysis that might show it.
Based on aerial photographs of the damage it caused, Fujita assigned the strongest tornado of the 1974 Super Outbreak, which affected Xenia, Ohio, a preliminary rating of F6 intensity ± 1 scale. The 1977 Birmingham–Smithfield F5 tornado's damage was surveyed by Ted Fujita and he "toyed with the idea of rating the Smithfield tornado an F6". In 2001, tornado expert Thomas P. Grazulis stated in his book F5–F6 Tornadoes; "In my opinion, if there ever was an F6 tornado caught on video, it was the Pampa, Texas tornado of 1995". In 2023, it was announced by the Storm Prediction Center and National Weather Service Norman, Oklahoma that the 1970 Lubbock tornado was originally rated F6, which was later downgraded to its official rating of F5.
Furthermore, the original wind speed numbers have since been found to be higher than the actual speeds required to incur the damage described at each category. The error manifests itself to an increasing degree as the category increases, especially in the range of F3 through F5. NOAA notes that "precise wind speed numbers are actually guesses and have never been scientifically verified. Different wind speeds may cause similar-looking damage from place to place—even from building to building. Without a thorough engineering analysis of tornado damage in any event, the actual wind speeds needed to cause that damage are unknown."