SES-2 Enclosure Management
The introduction of Serial Attached SCSI (SAS) as the most recent evolution of SCSI required redefining the related standard for enclosure management, called SCSI Enclosure Services. SES-2, or SCSI Enclosure Management 2 first revision, was introduced in 2002 and is now at revision 20. SES-2 SCSI Enclosure Services (SES) permit the management and sense the state of power supplies, cooling devices, LED displays, indicators, individual drives, and other non-SCSI elements installed in an enclosure. SES2 alerts users about drive, temperature and fan failures with an audible alarm and a fan failure LED.
The SES-2 command set uses the SCSI SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS commands to obtain configuration information for the enclosure and to set and sense standard bits for each element installed in the enclosure. The SEND DIAGNOSTIC command is used to send control information to internal or external LED indicators or to instruct one enclosure element to change its state or perform an operation.
The application client has two mechanisms for accessing the enclosure service process:
The SES-2 process handles a single primary subenclosure or multiple subenclosures. In the second case, one primary subenclosure will manage all the other secondary subenclosures.
Like SES, SES-2 establishes two types of thresholds for elements with limited sensing capability, like voltage, temperature, current etcetera: critical and warning. So for example in the case of temperature we may have:
When managed values fall within the warning range, the SES-2 processor will communicate a warning signal to the application client, typically a Host Bus Adapter (HBA). When values fall outside acceptable ranges, depending from the commands supported by the device server, the sense code shall be HARDWARE FAILURE or ENCLOSURE FAILURE.
SES-2 lists four types of reporting methods:
If you are a member of the T10 working group, the Standard, controlled by the T10 technical committee, can be found at:
Hub AI
SES-2 Enclosure Management AI simulator
(@SES-2 Enclosure Management_simulator)
SES-2 Enclosure Management
The introduction of Serial Attached SCSI (SAS) as the most recent evolution of SCSI required redefining the related standard for enclosure management, called SCSI Enclosure Services. SES-2, or SCSI Enclosure Management 2 first revision, was introduced in 2002 and is now at revision 20. SES-2 SCSI Enclosure Services (SES) permit the management and sense the state of power supplies, cooling devices, LED displays, indicators, individual drives, and other non-SCSI elements installed in an enclosure. SES2 alerts users about drive, temperature and fan failures with an audible alarm and a fan failure LED.
The SES-2 command set uses the SCSI SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS commands to obtain configuration information for the enclosure and to set and sense standard bits for each element installed in the enclosure. The SEND DIAGNOSTIC command is used to send control information to internal or external LED indicators or to instruct one enclosure element to change its state or perform an operation.
The application client has two mechanisms for accessing the enclosure service process:
The SES-2 process handles a single primary subenclosure or multiple subenclosures. In the second case, one primary subenclosure will manage all the other secondary subenclosures.
Like SES, SES-2 establishes two types of thresholds for elements with limited sensing capability, like voltage, temperature, current etcetera: critical and warning. So for example in the case of temperature we may have:
When managed values fall within the warning range, the SES-2 processor will communicate a warning signal to the application client, typically a Host Bus Adapter (HBA). When values fall outside acceptable ranges, depending from the commands supported by the device server, the sense code shall be HARDWARE FAILURE or ENCLOSURE FAILURE.
SES-2 lists four types of reporting methods: