Environmental control system
In aeronautics, an environmental control system (ECS) of an aircraft is an essential component which provides air supply, thermal control and cabin pressurization for the crew and passengers. Additional functions include the cooling of avionics, smoke detection, and fire suppression.
The systems described below are specific to current production Boeing airliners, although the details are essentially identical for passenger jets from Airbus and other companies. An exception was Concorde which had a supplementary air supply system fitted due to the higher altitudes at which it flew, and also the slightly higher cabin pressure it employed.
On jetliners, air is supplied to the ECS by being bled from a compressor stage of each gas turbine engine, upstream of the combustor. The temperature and pressure of this bleed air varies according to which compressor stage is used, and the power setting of the engine. A manifold pressure regulating shut-off valve (MPRSOV) restricts the flow as necessary to maintain the desired pressure for downstream systems.
A certain minimum supply pressure is needed to drive the air through the system, but it is desired to use as low a supply pressure as possible, because the energy the engine uses to compress the bleed air is not available for propulsion, and fuel consumption suffers. For this reason, air is commonly drawn from one of two (or in some cases such as the Boeing 777, three) bleed ports at different compressor stage locations. When the engine is at low pressure (low thrust or high altitude), the air is drawn from the highest pressure bleed port. As pressure is increased (more thrust or lower altitude) and reaches a predetermined crossover point, the high pressure shut-off valve (HPSOV) closes and air is selected from a lower pressure port to minimize the fuel performance loss. The reverse happens as engine pressure decreases.
To achieve the desired temperature, the bleed-air is passed through a heat exchanger called a pre-cooler. Air bled from the engine fan is blown across the pre-cooler, located in the engine strut, and absorbs excess heat from the service bleed air. A fan air modulating valve (FAMV) varies the cooling airflow to control the final air temperature of the service bleed air.
Notably, the Boeing 787 does not use bleed air to pressurize the cabin. The aircraft instead draws air from dedicated inlets, located ahead of the wings.
The primary component for the functioning of the cold air unit (CAU) is the Air Cycle Machine (ACM) cooling device. Some aircraft, including early Boeing 707 aircraft, used vapor-compression refrigeration like that used in home air conditioners.
An ACM uses no Freon: the air itself is the refrigerant. The ACM is preferred over vapor cycle devices because of reduced weight and maintenance requirements.
Environmental control system
In aeronautics, an environmental control system (ECS) of an aircraft is an essential component which provides air supply, thermal control and cabin pressurization for the crew and passengers. Additional functions include the cooling of avionics, smoke detection, and fire suppression.
The systems described below are specific to current production Boeing airliners, although the details are essentially identical for passenger jets from Airbus and other companies. An exception was Concorde which had a supplementary air supply system fitted due to the higher altitudes at which it flew, and also the slightly higher cabin pressure it employed.
On jetliners, air is supplied to the ECS by being bled from a compressor stage of each gas turbine engine, upstream of the combustor. The temperature and pressure of this bleed air varies according to which compressor stage is used, and the power setting of the engine. A manifold pressure regulating shut-off valve (MPRSOV) restricts the flow as necessary to maintain the desired pressure for downstream systems.
A certain minimum supply pressure is needed to drive the air through the system, but it is desired to use as low a supply pressure as possible, because the energy the engine uses to compress the bleed air is not available for propulsion, and fuel consumption suffers. For this reason, air is commonly drawn from one of two (or in some cases such as the Boeing 777, three) bleed ports at different compressor stage locations. When the engine is at low pressure (low thrust or high altitude), the air is drawn from the highest pressure bleed port. As pressure is increased (more thrust or lower altitude) and reaches a predetermined crossover point, the high pressure shut-off valve (HPSOV) closes and air is selected from a lower pressure port to minimize the fuel performance loss. The reverse happens as engine pressure decreases.
To achieve the desired temperature, the bleed-air is passed through a heat exchanger called a pre-cooler. Air bled from the engine fan is blown across the pre-cooler, located in the engine strut, and absorbs excess heat from the service bleed air. A fan air modulating valve (FAMV) varies the cooling airflow to control the final air temperature of the service bleed air.
Notably, the Boeing 787 does not use bleed air to pressurize the cabin. The aircraft instead draws air from dedicated inlets, located ahead of the wings.
The primary component for the functioning of the cold air unit (CAU) is the Air Cycle Machine (ACM) cooling device. Some aircraft, including early Boeing 707 aircraft, used vapor-compression refrigeration like that used in home air conditioners.
An ACM uses no Freon: the air itself is the refrigerant. The ACM is preferred over vapor cycle devices because of reduced weight and maintenance requirements.