Floor area
Floor area
from Wikipedia

In architecture, construction, and real estate, floor area, floor space, or floorspace is the area (measured in square metres or square feet) taken up by a building or part of it. The ways of defining "floor area" depend on what factors of the building should or should not be included, such as external walls, internal walls, corridors, lift shafts, stairs, etc. Generally there are three major differences in measuring floor area.[1]

  • Gross floor area (GFA) - The total floor area contained within the building measured to the external face of the external walls.
  • Gross internal area (GIA) - The floor area contained within the building measured to the internal face of the external walls.
  • Net internal area (NIA) (or Net floor area NFA, or Usable floor area UFA) - The NIA is the GIA less the floor areas taken up by lobbies, enclosed machinery rooms on the roof, stairs and escalators, mechanical and electrical services, lifts, columns, toilet areas (other than in domestic property), ducts, and risers.

Gross floor area

[edit]
Measuring gross floor area (GFA)

Gross floor area (GFA) in real estate is the total floor area inside the building envelope, including the external walls, and excluding the roof.

Definitions of GFA, including which areas are to be counted towards it and which areas aren't, vary around the world. Adding to this confusion is the practice among some developers to use gross leasable area (GLA) and GFA interchangeably, or to use GFA as GLA, even though GLA usually excludes corridors and other public areas inside the development, while both figures include areas occupied by structure, like walls and columns.

In Hong Kong

[edit]

Hong Kong law Chapter 123F, Building (Planning) Regulations, Regulation 23 sect 3 sub-paragraph (a) defined that:

Subject to sub-paragraph (b), for the purposes of regulations 19, 20, 21 and 22, the gross floor area of a building shall be the area contained within the external walls of the building measured at each floor level (including any floor below the level of the ground), together with the area of each balcony in the building, which shall be calculated from the overall dimensions of the balcony (including the thickness of the sides thereof), and the thickness of the external walls of the building.

sub-paragraph (b):

In determining the gross floor area for the purposes of regulations 20, 21 and 22, the Building Authority may disregard any floor space that he is satisfied is constructed or intended to be used solely for parking motor vehicles, loading or unloading of motor vehicles, or for refuse storage chambers, refuse storage and material recovery chambers, material recovery chambers, refuse storage and material recovery rooms, refuse chutes, refuse hopper rooms and other types of facilities provided to facilitate the separation of refuse to the satisfaction of the Building Authority, or for access facilities for telecommunications and broadcasting services, or occupied solely by machinery or equipment for any lift, air-conditioning or heating system or any similar service. (L.N. 406 of 1987; 39 of 2000 s. 7)

The non-accountable GFA is further defined in Practice Notes for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers no APP-2.[2]

Permitted GFA in Hong Kong land lease agreement generally the maximum GFA (excluding the non-accountable above) to develop. However it may be further reduced by the effect of plot ratio, maximum site coverage, maximum permitted height of building and Outline Zoning Plan. Moreover, roof and other uncovered area is exclude in Permitted GFA but usually had restricted use as opening space, corridor or emergence escaping area.

Green features

Since 2001, to encourage the incorporation of green features in building developments, further facilities could be excluded/disregard in GFA.[3] and defined at Joint Practice Notes on protection and improvement of the built and natural environment no. 1 and no. 2.[4][5] Since such facilities granted extra floor area to develop and usually included in the GFA/ selling area the developer sold to end-user, which made end-user confused, government planned to abolish the exclusion of green features and use alternative way to encourage green features. For the total floor area, HK use the term "site coverage".

In Singapore

[edit]

GFA in Singapore, defined by Urban Redevelopment Authority as of March 2014 is:[6]

3 Definition of gross floor area

3.1 All covered floor areas of a building, except otherwise exempted, and uncovered areas for commercial uses are deemed the gross floor area of the building for purposes of plot ratio control and development charge. The gross floor area is the total area of the covered floor space measured between the centre line of party walls, including the thickness of external walls but excluding voids. Accessibility and usability are not criteria for exclusion from GFA.

3.2 URA reserves the right to decide on GFA matters based on the specific design of a development proposal on a case-by-case basis.

With effect from January 2014, Private enclosed spaces (PES) and private roof terraces (PRT) are counted as part of the bonus GFA capped at 10% above the Master Plan that also includes balconies.[7]

Gross leasable area

[edit]

Gross leasable area (GLA) is the amount of floor space available to be rented in a commercial property. Specifically, gross leasable area is the total floor area designed for tenant occupancy and exclusive use, including any basements, mezzanines, or upper floors. It is typically expressed in square metres (although in some places such as the United States, Canada and the United Kingdom, the square foot is used). It is measured from the center line of joint partitions and from outside wall faces. That is, gross leasable area is the area for which tenants pay rent, and thus the area that produces income for the property owner.

For a property with only one tenant, the measurements gross floor area (GFA) and gross leasable area (GLA) are essentially equal.

The Building Owners and Managers Association has established a standard with American National Standards Institute, ANSI/BOMA Z65.1-1996 for measuring floor area and calculating gross leasable area and loss factor.[8]

See also

[edit]

References

[edit]
[edit]
Revisions and contributorsEdit on WikipediaRead on Wikipedia
from Grokipedia
Floor area refers to the total horizontal expanse of the floors in a building or , most commonly quantified as gross floor area, which encompasses the space within the inside perimeter of the exterior , excluding vent shafts and courts, without deductions for corridors, stairways, ramps, closets, interior wall thicknesses, columns, or other features. For or portions without surrounding exterior , it is measured as the usable area under the horizontal projection of the or above, and it excludes shafts with no openings or interior courts. Distinctions exist between types of floor area to serve specific regulatory and practical purposes. Net floor area measures the actual occupied space, excluding unoccupied accessory areas such as corridors, stairways, ramps, toilet rooms, mechanical rooms, and closets. Building area, meanwhile, defines the within exterior walls or firewalls, also excluding vent shafts and open courtyards, and is used to limit overall building size based on fire hazards and types. These measurements adhere to standards like those in the International Building Code (IBC), where gross floor area informs occupant load calculations, while net floor area refines estimates of usable space. A key application of floor area is in the , which calculates the ratio of a building's total gross floor area to the size of its lot or parcel, expressed as a (e.g., FAR = gross floor area ÷ buildable land area). Originating in early 20th-century U.S. practices—proposed by engineer Reginald P. in a 1913 New York report and formalized in New York City's 1940 resolution—FAR regulates development intensity by capping building volume relative to land size, with values ranging from 0.30 in low-density zones to 16.0 in high-intensity commercial areas. This metric promotes flexible design while controlling , traffic generation, and environmental impacts, making it essential for ordinances and . In and , floor area metrics underpin property valuation, leasing agreements, and construction budgeting; for instance, gross area aids in compliance and overall , while rentable and usable areas (subsets of gross and net) determine tenant allocations in multi-tenant buildings. By standardizing these calculations, floor area ensures , equitable development, and efficient utilization across residential, commercial, and industrial contexts.

Basic Concepts

Definition

Floor area in and refers to the total horizontal extent of all levels within a building, calculated as a two-dimensional projection rather than a three-dimensional that would include height or cubic capacity. This measure emphasizes the planar surface area of floors, distinguishing it from building , which accounts for vertical dimensions and is used for assessments like loads or structural capacity. The core definition encompasses the sum of areas across all floors, typically measured from the interior perimeter of exterior walls or structural boundaries, excluding voids such as vent shafts or interior courts unless otherwise specified in standards. It includes essential components like habitable living spaces, circulation areas such as hallways and stairways, and utility spaces like mechanical rooms, while generally excluding unenclosed external features like balconies or terraces that do not form part of the building's interior envelope. The terminology of floor area evolved in the early alongside the development of modern zoning regulations, which sought to control building density through quantifiable spatial metrics; for instance, New York City's 1916 Zoning Resolution introduced regulations on building bulk via setbacks and lot coverage, which indirectly influenced later concepts of floor area limits to regulate urban growth. Floor area measurements can be categorized broadly as gross, which includes most internal features, or , which deducts certain non-usable spaces, though specifics vary by context.

Importance

Floor area serves as a fundamental metric in assessing building efficiency, enabling architects and engineers to optimize utilization by balancing structural elements, circulation paths, and functional zones within a given . This measurement directly influences cost estimation during the phase, as it correlates with material requirements, labor, and overall expenses; for instance, higher floor area ratios can increase budgets in urban developments due to vertical needs. In terms of utilization, it guides decisions on allocating areas for core functions versus support spaces, promoting sustainable designs that minimize wasted while maximizing occupant . Economically, floor area underpins critical financial aspects of , forming the basis for property taxation in many jurisdictions where assessments incorporate floor area into the evaluated value, multiplied by local rates; liabilities vary widely by location. It also determines rates, with leases typically structured on a per-square-foot basis—such as net leasable area driving premiums in retail spaces—directly impacting streams for owners and operational costs for tenants. premiums similarly hinge on floor area, as insurers use it to gauge risk exposure from , , or structural failure, with larger footprints generally increasing coverage costs in high-risk zones. From a perspective, floor area profoundly affects layout choices, dictating the arrangement of rooms, hallways, and amenities to enhance functionality and ensure occupant comfort through adequate , ventilation, and . Constraints on floor area, often imposed by site limitations, compel innovative solutions like multi-story configurations or open-plan interiors, which can improve energy efficiency by reducing the building's surface-to-volume . This metric fosters user-centered environments, as evidenced in residential projects where optimized floor area contributes to higher satisfaction scores, with studies showing a 10-20% uplift in perceived livability when space is efficiently distributed. Legally and regulatorily, floor area holds significant weight as a core compliance indicator for obtaining building permits and adhering to standards, where exceeding allowable limits can result in denials or costly redesigns. It is integral to laws that cap development via floor area ratios, ensuring urban harmony by preventing overcrowding and preserving infrastructure capacity; violations can lead to substantial fines in densely populated cities for non-compliant expansions. Additionally, it informs protocols, with egress requirements scaled to occupant load derived from floor area, thereby safeguarding public welfare in emergencies.

Types of Floor Area

Note: Definitions of floor area types can vary by standard and jurisdiction. For example, the International Building Code (IBC) used in the often differs from international standards like ISO 9836:2017 or BOMA guidelines for commercial spaces. The following descriptions reference primary standards where applicable.

Gross Floor Area

Gross floor area (GFA), also known as gross square feet (GSF), represents the total enclosed area of a building measured from the outside faces of its exterior walls across all floors. This measurement encompasses the entirety of the structure's horizontal extents, providing a comprehensive assessment of its overall size without exclusions for internal configurations. According to the Postsecondary Facilities Inventory and Manual (FICM), GFA is defined as "the sum of all areas on all floors of a building included within the outside faces of its exterior walls, including all vertical penetration areas—for stairs, elevator shafts, mechanical shafts, and ducts." This standard, developed by the (NCES), emphasizes that GFA shall include basements, mezzanines, intermediate floors, penthouses, and any usable spaces above the roof, ensuring a holistic capture of the building's . The inclusion criteria for GFA are deliberately broad to account for all structural and support elements. Exterior walls serve as the boundary for measurement, incorporating their thickness, while vertical penetrations such as stairwells, shafts, and duct spaces are fully counted on each level they traverse. Non-usable spaces like mechanical rooms, shafts, and internal walls are also included, as are areas occupied by columns and other load-bearing features. Limitations apply to exclude uncovered external areas, such as open balconies or parking lots. The International Property Measurement Standards (IPMS) align with this approach in their IPMS 1 , measuring to the outer perimeter of external features on a floor-by-floor basis to sum the total occupiable and non-occupiable enclosed spaces. GFA is primarily used in construction for estimating total project costs, material requirements, and structural , as it provides an unadjusted baseline for the building's scale. In , it serves as a key metric for calculating floor area ratios (FAR), which regulate development density and ensure compliance with guidelines by relating building size to lot area. For instance, the American Planning Association notes that GFA is "the sum of the gross horizontal areas of the several floors of all on the lot, measured from the exterior faces of exterior walls," facilitating equitable assessments of intensity. A practical example is a multi-story office building where GFA is calculated by summing the areas of all levels, including office spaces, corridors, stairwells, and elevator shafts, without deductions for circulation or support areas. This total might yield 100,000 square feet for a five-story , each floor measuring 20,000 square feet from exterior walls, aiding architects and planners in evaluating the project's overall and efficiency. In contrast to net floor area, which excludes such non-usable spaces, GFA offers a more inclusive view for high-level sizing.

Net Floor Area

Net floor area refers to the usable interior space within a building, excluding structural elements, walls, and certain non-primary areas, though definitions vary by standard. According to ISO 9836:2017, net floor area is the area within the enclosing elements, comprising the sum of usable area (for intended occupancy), services area (e.g., mechanical rooms), and circulation area (e.g., corridors, stairwells). It is measured to the internal face of enclosing walls, excluding thicknesses of structural elements like exterior and interior walls, columns, and piers. In contrast, building codes such as the International Building Code (IBC) define net floor area more narrowly for purposes like occupant load calculations, excluding unoccupied accessory spaces such as corridors, stairways, ramps, toilet rooms, mechanical rooms, and closets. Vertical penetrations like lift shafts may also be deducted in these contexts. The measurement boundary is from the interior face of walls to the limits of the defined usable space, ensuring accuracy in assessing functional extents. For instance, in residential units under IBC guidelines, net floor area would include living rooms and bedrooms but exclude utility closets and mechanical spaces. This approach derives from gross floor area by subtracting non-usable components, highlighting the focus on practical interior usability.

Gross Leasable Area

Gross Leasable Area () refers to the total rentable floor space within a , calculated as the sum of areas available for tenant and the associated rent payments, encompassing both exclusive tenant spaces and proportional allocations of select common areas. This measurement is particularly prevalent in retail and mixed-use developments, where it quantifies the revenue-generating potential of leasable square footage. According to standards from the Building Owners and Managers Association (BOMA), GLA focuses on spaces that directly contribute to tenant operations while ensuring fair distribution of shared amenities. Key inclusion criteria for comprise the primary tenant areas—such as sales floors, storage, and offices—plus each tenant's pro-rata share of essential common elements like corridors, restrooms, and lobbies. These shared spaces are apportioned based on the ratio of a tenant's individual leasable area to the building's overall , reflecting the indirect benefits tenants derive from them without granting exclusive control. This approach aligns with BOMA's Retail Standard, which emphasizes equitable allocation to support the "retail experience" while excluding non-leasable elements like mechanical rooms or exterior unless specifically designated. GLA is generally measured from the demising walls, defined as the partitions separating tenant suites from adjacent common or other tenant areas, with calculations extending to the centerline of these walls for precision. This method, outlined in BOMA guidelines, ensures consistent boundary delineation and avoids overlap in multi-tenant settings, incorporating finished floor surfaces across levels including basements and mezzanines where applicable. In a typical scenario, encompasses the full floor area of individual retail stores up to their lines but prorates contributions from expansive atrium access zones among all tenants proportional to their leased , thereby integrating circulation benefits into the rentable metric without inflating individual store measurements.

Calculation Methods

General Principles

Floor area calculations rely on standardized techniques to ensure consistency and accuracy across building types. Basic methods include planimetric measurement, which derives areas from two-dimensional architectural floor plans by tracing external perimeters and computing enclosed spaces, and , a three-dimensional technique that captures point clouds for precise as-built verification, particularly useful for irregular or renovated structures. Horizontal projection rules apply to open or partially enclosed areas, defining floor area as the usable space beneath the horizontal plane of the overlying or floor, excluding projections like beyond structural limits. The formula for total floor area involves summing the measured areas of all individual levels within the building's exterior , with adjustments for geometric irregularities such as cantilevers or voids. For structures with uniform stories, this equates to the area of one representative multiplied by the number of stories, though deviations require level-by-level to maintain precision. Inclusions and deductions address structural variations: basements are included in gross floor area if they are within the exterior walls and under the horizontal projection of the floor or above. Mezzanines are included in gross floor area; however, if their area exceeds one-third of the room below, they may be considered a separate story for purposes. For net or usable floor area, areas under sloped roofs or ceilings qualify only where the vertical clearance is at least 5 feet (1.5 m) over 50 percent or more of the space, with portions below this threshold excluded from habitable room area calculations. CAD software facilitates accurate computation by importing plans, automating area delineations, and generating reports with tolerances under 2%, reducing human error in complex geometries. The International Property Measurement Standards (IPMS) promote global uniformity in area measurements.

Regional Variations

In the United States, floor area calculations for commercial properties follow the standards set by the Building Owners and Managers Association International (BOMA). For offices, the 2024 Office Standard (ANSI/BOMA Z65.1-2024) defines Rentable Area as the usable space allocated to tenants, including a share of common areas. For retail properties, Gross Leasable Area (GLA) is the total floor area available for tenant occupancy and exclusive use, including accessory spaces such as mechanical rooms and restrooms but excluding common areas like lobbies and stairwells. In zoning contexts, parking structures are sometimes included in gross floor area computations to regulate overall development density, though exemptions apply in certain municipalities—for instance, up to 400 square feet of garage area per lot may be excluded from floor area ratio (FAR) limits in some urban codes. Across , the European Union's Energy Performance of Buildings Directive (EPBD), recast in 2024, mandates standardized floor area metrics—such as heated or conditioned floor area—for evaluating energy efficiency in , aiming to reduce consumption by integrating these measurements into national building codes and systems like the . This directive influences regional variations by requiring member states to account for energy-relevant spaces, potentially leading to deductions or exclusions for features like green roofs and internal green spaces that enhance insulation and , as seen in implementations under the directive's targets for public buildings. In , Hong Kong's gross floor area (GFA) calculations incorporate plot ratio restrictions under the Buildings Ordinance, with bonuses granted for integrating public facilities into private developments; for example, developers receive additional GFA—up to five times the surrendered area or 20% of the permissible plot ratio, whichever is less—for dedicating spaces to public passages, open spaces, or non-profit facilities like community halls. Similarly, in , the (URA) enforces strict GFA inclusions, where balconies are generally counted as part of the total floor area unless qualifying for bonuses under the Balcony Incentive Scheme (capped at 15% of the unit's internal net area), and voids (such as atriums or double-volume spaces) are typically excluded to prevent inefficient space utilization, though structural elements like slabs within voids remain included. In the , the Royal Institution of Chartered Surveyors (RICS) Code of Measuring Practice outlines guidelines for floor area measurement, excluding external unenclosed areas (such as open balconies or terraces) from Gross Internal Area () calculations to focus on usable internal space, while Gross External Area (GEA) includes the building's footprint within external walls but omits low-headroom spaces under 1.5 meters. These RICS standards align with International Property Measurement Standards (IPMS), which further differentiate by excluding unfinished external areas from internal measurements. Regional variations in (FAR) integration reflect local priorities, such as density control in high-growth areas; for instance, while the often ties FAR to exemptions for , and use it to incentivize public amenities through GFA bonuses, and European approaches link it to energy directives for sustainable urban form, contrasting with the UK's emphasis on precise internal area exclusions for valuation purposes.

Applications

In Building Regulations

Floor area plays a critical role in building regulations to ensure , particularly in and structural integrity. In fire codes, floor area determines occupant load calculations, which in turn dictate the number, width, and configuration of egress paths. Under the International Building Code (IBC) (2024 edition), occupant load is computed by dividing the floor area by an occupant load factor specific to the occupancy type, such as 150 gross square feet per occupant for business areas or 5 net square feet per occupant for standing spaces in assembly areas. This ensures adequate means of egress; for instance, buildings require at least two exits when the occupant load exceeds 500, with minimum egress widths adjusted based on these loads—0.2 inches per occupant for stairways in sprinklered buildings versus 0.3 inches in unsprinklered ones. Sprinkler requirements are also tied to floor area thresholds, often termed "fire area," where automatic systems become mandatory if the fire area surpasses limits like 12,000 square feet for Group A-1, A-3, A-4 assembly or educational occupancies, or 5,000 square feet for Group A-2 restaurants. These provisions, harmonized with NFPA standards, reduce travel distances for egress (e.g., up to 250 feet in sprinklered buildings versus 200 feet without) and enhance overall life . Building height and area allowances further integrate floor area metrics to limit risks based on occupancy and construction type, as outlined in IBC Chapter 5 (2024). Tables 504.3, 504.4, and 506.2 specify maximum s, stories, and areas per story; for example, a non-sprinklered Type V-B wood-framed building in () is restricted to 50 feet in , 1 story, and 9,000 square feet per story, while Type I-A non-combustible permits unlimited and area for the same . Sprinkler systems provide increases, such as up to 200% more area for certain types, promoting safer designs by allowing larger footprints only with enhanced fire suppression. Compliance examples illustrate this: in a Type II-B protected non-combustible structure for mercantile (Group M) use, the allowable area per story rises from 18,500 square feet without sprinklers to 27,750 square feet with them (1.5x increase), ensuring that larger floor areas correlate with materials and systems that mitigate fire spread. These limits prevent overcrowding and facilitate emergency response across diverse occupancies like assembly, industrial, and residential. The 2024 IBC emphasizes resilient design, incorporating floor area considerations into seismic provisions under Chapter 16 to enhance building performance in high-risk zones. Updates align with ASCE 7-22 standards, where floor area influences seismic calculations for load resistance, requiring designs that account for distributed weight in multi-story structures to avoid during earthquakes. For instance, increased area allowances for timber in seismic categories promote sustainable, resilient buildings by expanding permissible footprints up to 75,000 square feet per story in Type IV-A (with up to 100% exposed timber elements permitted), while maintaining structural . These changes support broader resilience goals, ensuring floor area metrics balance density with safety in earthquake-prone regions.

In Real Estate

In , floor area is a critical determinant in valuation, serving as the primary basis for square pricing models where appraisers estimate by multiplying the measured floor area—often gross internal area () or net leasable area—by comparable per-square-foot rates derived from recent transactions. This approach ensures uniformity in assessments, with adjustments made for factors like , condition, and building efficiency, as outlined in standards that emphasize accurate to avoid valuation disputes. For instance, residential and commercial appraisals frequently rely on GIA to capture the total enclosed space, providing a reliable input for capitalization or sales comparison methods. Leasing practices in hinge on specific floor area metrics to standardize rental calculations and tenant obligations. In retail properties, gross leasable area (GLA) forms the foundation for rent determination, encompassing all tenant-occupied spaces measured to the outer face of exterior walls and the centerline of demising walls, excluding common areas like malls or parking. This metric enables landlords to set base rents on a per-square-foot basis, directly tying to the total rentable square footage available for exclusive tenant use. In contrast, office leasing typically employs net floor area (NFA), which measures the usable space within demising walls, augmented by add-on factors ranging from 15% to 25% to allocate shares of common areas such as lobbies and restrooms, yielding the total rentable square footage billed to tenants. Floor area significantly influences property yields and investment decisions by scaling potential income streams relative to capital outlay. Larger effective floor areas, particularly when optimized for high , boost net operating through increased rental revenue, thereby lowering capitalization rates and enhancing overall yields—often targeting 6-8% for stabilized commercial assets. Investors prioritize properties with efficient floor area utilization, as it mitigates vacancy risks and supports higher internal rates of return, guiding choices in portfolio diversification and acquisition strategies. For example, developments with higher leasable floor areas can achieve superior cash-on-cash returns by maximizing revenue per site footprint. As of 2025, hybrid work models have led organizations to reduce effective floor area needs by 10-50% through flexible designs emphasizing shared spaces over dedicated desks. Recent surveys indicate that a of companies continue to reconfigure layouts for hybrid integration, lowering demand for traditional footprints and influencing investments toward adaptable, multi-use . This trend has reshaped leasing dynamics, favoring shorter-term flexible arrangements that optimize underutilized space and improve yield resilience amid evolving workforce patterns.

In Urban Planning

In urban planning, floor area plays a central role through the Floor Area Ratio (FAR), which measures development intensity by dividing the total gross floor area (GFA) of buildings on a site by the site's total area, expressed as FAR = Total GFA / Site Area. This metric helps planners regulate building density, ensuring balanced that supports capacity and community livability. Zoning ordinances frequently employ FAR limits to curb by capping how much floor area can be developed on a given lot, thereby promoting compact growth and preserving open spaces. These restrictions also influence heights, as higher FAR allowances enable taller structures to accommodate more floor area vertically, while lower limits maintain lower profiles in sensitive areas. By integrating FAR into codes, cities like New York control the scale of development to align with transportation networks and environmental goals, preventing overdevelopment that could strain resources. Floor area efficiency ties into sustainability efforts, particularly in green building certifications such as , where metrics evaluate energy use and resource consumption per unit of floor area to encourage denser, more efficient designs. -certified buildings, for instance, demonstrate 18–39% lower per floor area compared to conventional structures, highlighting how optimized floor area contributes to reduced carbon footprints and enhanced . This approach supports broader objectives by linking floor area utilization to metrics like daylight access and material efficiency, fostering sustainable cityscapes. Illustrative examples underscore FAR's variability: in dense urban centers like , high FAR values—reaching up to 13.0 in central districts—facilitate vertical development to maximize limited land, supporting high population densities without excessive sprawl. In contrast, suburban zones often impose low FAR caps, such as 0.5 or less for single-family residential areas, to preserve green spaces and low-rise character, as seen in many U.S. municipalities where such limits maintain a spacious, low-density environment. These differences illustrate how FAR tailoring adapts to local contexts, balancing growth with .