Hubbry Logo
search button
Sign in
Pipe flow
Pipe flow
Comunity Hub
History
arrow-down
starMore
arrow-down
bob

Bob

Have a question related to this hub?

bob

Alice

Got something to say related to this hub?
Share it here.

#general is a chat channel to discuss anything related to the hub.
Hubbry Logo
search button
Sign in
Pipe flow
Community hub for the Wikipedia article
logoWikipedian hub
Welcome to the community hub built on top of the Pipe flow Wikipedia article. Here, you can discuss, collect, and organize anything related to Pipe flow. The purpose of the hub is to connect people, foste...
Add your contribution
Pipe flow

In fluid mechanics, pipe flow is a type of fluid flow within a closed conduit, such as a pipe, duct or tube. It is also called as Internal flow.[1] The other type of flow within a conduit is open channel flow. These two types of flow are similar in many ways, but differ in one important aspect. Pipe flow does not have a free surface which is found in open-channel flow. Pipe flow, being confined within closed conduit, does not exert direct atmospheric pressure, but does exert hydraulic pressure on the conduit.

Not all flow within a closed conduit is considered pipe flow. Storm sewers are closed conduits but usually maintain a free surface and therefore are considered open-channel flow. The exception to this is when a storm sewer operates at full capacity, and then can become pipe flow.

Energy in pipe flow is expressed as head and is defined by the Bernoulli equation. In order to conceptualize head along the course of flow within a pipe, diagrams often contain a hydraulic grade line (HGL). The viscous shear forces in the fluid causes pipe flow to experience frictional losses as defined by the Darcy-Weisbach formula.

Laminar-turbulence transition

[edit]

The behavior of pipe flow is governed mainly by the effects of viscosity and gravity relative to the inertial forces of the flow. Depending on the effect of viscosity relative to inertia, as represented by the Reynolds number, the flow can be either laminar or turbulent. For circular pipes of different surface roughness, at a Reynolds number below the critical value of approximately 2000[2] pipe flow will ultimately be laminar, whereas above the critical value turbulent flow can persist, as shown in Moody chart. For non-circular pipes, such as rectangular ducts, the critical Reynolds number is shifted, but still depending on the aspect ratio.[3] Earlier transition to turbulence, happening at Reynolds number one order of magnitude smaller, i.e. ,[4] can happen in channels with special geometrical shapes, such as the Tesla valve.

Flow through pipes can roughly be divided into two:

See also

[edit]

References

[edit]
  1. ^ Çengel, Yunus A.; Cimbala, John M. (2006). Fluid mechanics: fundamentals and applications. McGraw-Hill series in mechanical engineering. Boston, Mass.: McGraw-Hill Higher Education. p. 321. ISBN 978-0-07-247236-3.
  2. ^ Avila, K.; D. Moxey; A. de Lozar; M. Avila; D. Barkley; B. Hof (July 2011). "The Onset of Turbulence in Pipe Flow". Science. 333 (6039): 192–196. Bibcode:2011Sci...333..192A. doi:10.1126/science.1203223. PMID 21737736. S2CID 22560587.
  3. ^ Hanks, Richard W.; H-C. Ruo (1966). "Laminar-turbulent transition in ducts of rectangular cross section". Industrial & Engineering Chemistry Fundamentals. 5 (4): 558–561. doi:10.1021/i160020a022.
  4. ^ Nguyen, Quynh M.; Abouezzi, Joanna; Ristroph, Leif (17 May 2021). "Early turbulence and pulsatile flows enhance diodicity of Tesla's macrofluidic valve". Nature Communications. 12 (12): 2884. arXiv:2103.17222. Bibcode:2021NatCo..12.2884N. doi:10.1038/s41467-021-23009-y. PMC 8128925. PMID 34001882.

Further reading

[edit]
  • Chow, V. T. (1959/2008). Open-Channel Hydraulics. Caldwell, New Jersey: Blackburn Press. ISBN 9780070859067.