Hubbry Logo
search
logo
2176093

Prothrombin time

logo
Community Hub0 Subscribers
Write something...
Be the first to start a discussion here.
Be the first to start a discussion here.
See all
Prothrombin time

The prothrombin time (PT) – along with its derived measures of prothrombin ratio (PR) and international normalized ratio (INR) – is an assay for evaluating the extrinsic pathway and common pathway of coagulation. This blood test is also called protime INR and PT/INR. They are used to determine the clotting tendency of blood, in conditions such as the measure of warfarin dosage, liver damage (cirrhosis), and vitamin K status. PT measures the following coagulation factors: I (fibrinogen), II (prothrombin), V (proaccelerin), VII (proconvertin), and X (Stuart–Prower factor).

PT is often used in conjunction with the activated partial thromboplastin time (aPTT) which measures the intrinsic pathway and common pathway of coagulation.[citation needed]

The reference range for prothrombin time depends on the analytical method used, but is usually around 12–13 seconds (results should always be interpreted using the reference range from the laboratory that performed the test), and the INR in absence of anticoagulation therapy is 0.8–1.2. The target range for INR in anticoagulant use (e.g. warfarin) is 2 to 3. In some cases, if more intense anticoagulation is thought to be required, the target range may be as high as 2.5–3.5 depending on the indication for anticoagulation.

Prothrombin time is typically analyzed by a laboratory technologist on an automated instrument at 37 °C (as a nominal approximation of normal human body temperature).[citation needed]

The prothrombin time ratio is the ratio of a subject's measured prothrombin time (in seconds) to the normal laboratory reference PT. The PT ratio varies depending on the specific reagents used, and has been replaced by the INR. Elevated INR may be useful as a rapid and inexpensive diagnostic of infection in people with COVID-19.

The result (in seconds) for a prothrombin time performed on a normal individual will vary according to the type of analytical system employed. This is due to the variations between different types and batches of manufacturer's tissue factor used in the reagent to perform the test. The INR was devised to standardize the results. Each manufacturer assigns an ISI value (International Sensitivity Index) for any tissue factor they manufacture. The ISI value indicates how a particular batch of tissue factor compares to an international reference tissue factor. The ISI is usually between 0.94 and 1.4 for more sensitive and 2.0–3.0 for less sensitive thromboplastins.

The INR is the ratio of a patient's prothrombin time to a normal (control) sample, raised to the power of the ISI value for the analytical system being used.

PTnormal is established as the geometric mean of the prothrombin times (PT) of a reference sample group.

See all
User Avatar
No comments yet.