Ligand (biochemistry)
Ligand (biochemistry)
Main page
1990088

Ligand (biochemistry)

logo
Community Hub0 subscribers
What are your thoughts?
Be the first to start a discussion here.
Be the first to start a discussion here.
Ligand (biochemistry)

In biochemistry and pharmacology, a ligand is a substance that forms a complex with a biomolecule to serve a biological purpose. The etymology stems from Latin ligare, which means 'to bind'. In protein-ligand binding, the ligand is usually a molecule which produces a signal by binding to a site on a target protein. The binding typically results in a change of conformational isomerism (conformation) of the target protein. In DNA-ligand binding studies, the ligand can be a small molecule, ion, or protein which binds to the DNA double helix. The relationship between ligand and binding partner is a function of charge, hydrophobicity, and molecular structure.

Binding occurs by intermolecular forces, such as ionic bonds, hydrogen bonds and Van der Waals forces. The association or docking is actually reversible through dissociation. Measurably irreversible covalent bonding between a ligand and target molecule is atypical in biological systems. In contrast to the definition of ligand in metalorganic and inorganic chemistry, in biochemistry it is ambiguous whether the ligand generally binds at a metal site, as is the case in hemoglobin. In general, the interpretation of ligand is contextual with regards to what sort of binding has been observed.

Ligand binding to a receptor protein alters the conformation by affecting the three-dimensional shape orientation. The conformation of a receptor protein composes the functional state. Ligands include substrates, inhibitors, activators, signaling lipids, and neurotransmitters. The rate of binding is called affinity, and this measurement typifies a tendency or strength of the effect. Binding affinity is actualized not only by host–guest interactions, but also by solvent effects that can play a dominant, steric role which drives non-covalent binding in solution. The solvent provides a chemical environment for the ligand and receptor to adapt, and thus accept or reject each other as partners.

Radioligands are radioisotope labeled compounds used in vivo as tracers in PET studies and for in vitro binding studies.

The interaction of ligands with their binding sites can be characterized in terms of a binding affinity. In general, high-affinity ligand binding results from greater attractive forces between the ligand and its receptor while low-affinity ligand binding involves less attractive force. In general, high-affinity binding results in a higher occupancy of the receptor by its ligand than is the case for low-affinity binding; the residence time (lifetime of the receptor-ligand complex) does not correlate. High-affinity binding of ligands to receptors is often physiologically important when some of the binding energy can be used to cause a conformational change in the receptor, resulting in altered behavior for example of an associated ion channel or enzyme.

A ligand that can bind to and alter the function of the receptor that triggers a physiological response is called a receptor agonist. Ligands that bind to a receptor but fail to activate the physiological response are receptor antagonists.

Agonist binding to a receptor can be characterized both in terms of how much physiological response can be triggered (that is, the efficacy) and in terms of the concentration of the agonist that is required to produce the physiological response (often measured as EC50, the concentration required to produce the half-maximal response). High-affinity ligand binding implies that a relatively low concentration of a ligand is adequate to maximally occupy a ligand-binding site and trigger a physiological response. Receptor affinity is measured by an inhibition constant or Ki value, the concentration required to occupy 50% of the receptor. Ligand affinities are most often measured indirectly as an IC50 value from a competition binding experiment where the concentration of a ligand required to displace 50% of a fixed concentration of reference ligand is determined. The Ki value can be estimated from IC50 through the Cheng Prusoff equation. Ligand affinities can also be measured directly as a dissociation constant (Kd) using methods such as fluorescence quenching, isothermal titration calorimetry or surface plasmon resonance.

Low-affinity binding (high Ki level) implies that a relatively high concentration of a ligand is required before the binding site is maximally occupied and the maximum physiological response to the ligand is achieved. In the example shown to the right, two different ligands bind to the same receptor binding site. Only one of the agonists shown can maximally stimulate the receptor and, thus, can be defined as a full agonist. An agonist that can only partially activate the physiological response is called a partial agonist. In this example, the concentration at which the full agonist (red curve) can half-maximally activate the receptor is about 5 x 10−9 Molar (nM = nanomolar).