Recent from talks
Nothing was collected or created yet.
Moisture sensitivity level
View on WikipediaThis article needs additional citations for verification. (October 2020) |
Moisture sensitivity level (MSL) relates to the packaging and handling precautions for some semiconductors and is a rating that shows a device's susceptibility to damage due to absorbed moisture when subjected to reflow soldering as defined in J-STD-020. The MSL is an electronic standard for the time period in which a moisture sensitive device can be exposed to ambient room conditions (30 °C/85%RH at Level 1; 30 °C/60%RH at all other levels) without taking measures to retard the absorption of moisture.
Modern semiconductors are typically encapsulated in molded plastic. This plastic absorbs and retains moisture from ambient air. When a semiconductor package is soldered or de-soldered, it is subjected to rapid heating. The increase in temperature will cause trapped moisture to turn to vapor, seek to expand and escape the package. The process of moisture expansion and escape can be violent and result in internal separation (delamination) of the plastic from the die or lead-frame, wire bond damage, die damage, and internal cracks. (Most of this damage is generally not visible on the component external surface and must be assessed by acoustic microscopy and/or X-ray radiology.) In more extreme cases, cracks will extend to the component surface. In the most severe cases, the component will bulge and pop, in what is commonly known as the "popcorn" effect.
Typical methods to reduce the risk of damage include: 1) baking the components at a temperature near or above 100 °C before soldering, 2) storage of susceptible components in moisture barrier bags after baking and 3) employing pre-heating of the area of the printed circuit board before soldering to decrease the temperature transient that the package will be subjected to.
Moisture sensitivity levels are specified in technical standard IPC/JEDEC Moisture/reflow Sensitivity Classification for Nonhermetic Surface-Mount Devices.[1] The times indicate how long components can be outside of dry storage before they have to be baked to remove any absorbed moisture.
- MSL 6 – Mandatory bake before use
- MSL 5a – 24 hours
- MSL 5 – 48 hours
- MSL 4 – 72 hours
- MSL 3 – 168 hours
- MSL 2a – 4 weeks
- MSL 2 – 1 year
- MSL 1 – Unlimited floor life
Moisture sensitive devices are packaged in a moisture barrier antistatic bag with a desiccant and a moisture indicator card which is sealed.
Practical
[edit]MSL-specified parts must be baked before assembly if their exposure has exceeded the rating. The approved degree of baking depends upon the thickness of the package, the exposure time to moisture, the relative humidity of the atmosphere it was exposed to and the MSL rating of the part, with thinner packages generally expected to need less baking time and at lower temperatures.[2]
For example, an end user of a SOT-223, MSL 3 package (1.8 mm thickness) that has been exposed to typical ambient air conditions for 72 hours longer than its floor life (168 hours) would need to perform a 27-hour bake at 120 °C before soldering but under the same ambient conditions using a VQFN-24, MSL 3 package (0.85 mm thickness) that user would have to perform an 8-hour bake at the same temperature.[3] It is expected that the user solders the part within a few minutes to a few hours after bake and cool down completes, as the part will commence absorbing moisture again as soon as the package cools. Baking at temperatures between 90° and 120 °C is generally not recommended to exceed 96 hours over concerns of promoting oxidation and/or intermetallic growth, however, baking at temperatures under 90° has no practical time limit.[4]
Once soldered, moisture sensitivity is generally no longer a consideration. This is because the MSL rating is concerned with the process of soldering or desoldering, which introduces relatively rapid high-temperature stress to the part. During normal use, including when power is applied, the plastic package is unlikely to encounter temperature conditions similar to soldering itself.
Though MSL standards are explicitly not meant to be applied during manual soldering and rework,[5] manual rework temperature rise conditions may approach that of reflow soldering over a portion of, or the entire, package. The user should evaluate whether ignoring MSL bake conditions is appropriate in their circumstances.
References
[edit]- ^ "Moisture/reflow Sensitivity Classification for Nonhermetic Solid State Surface-mount Devices". JEDEC. Retrieved 11 August 2022.
- ^ [2] JEDEC J-STD-033D, Retrieved 6 April, 2025.
- ^ [3] JEDEC J-STD-033D, Table 4-1. Retrieved 6 April, 2025.
- ^ [4] JEDEC J-STD-033D, Section 4.2.7.1. Retrieved 6 April, 2025.
- ^ [5] JEDEC J-STD-033D, Section 1.3.4. Retrieved 6 April, 2025.
External links
[edit]Moisture sensitivity level
View on GrokipediaDefinition and Background
Definition
Moisture sensitivity level (MSL) is an industry-standard rating system that classifies the vulnerability of nonhermetic surface-mount devices (SMDs) to damage from moisture absorption during storage and handling prior to reflow soldering. It specifies the maximum allowable exposure time, known as floor life, that a moisture-sensitive device (MSD) can endure under controlled ambient conditions—typically 30°C and 60% relative humidity—before it must undergo protective measures such as baking to remove absorbed moisture. This classification ensures components maintain integrity through the assembly process, as outlined in the IPC/JEDEC J-STD-020 standard, first published in April 1999 with the latest revision J-STD-020F in November 2022.[1] In plastic-encapsulated microelectronics, moisture diffuses through the permeable epoxy molding compound and adheres to internal surfaces, such as the die paddle or leadframe. During reflow soldering, where temperatures can exceed 220°C, this absorbed moisture rapidly vaporizes, generating high internal pressure that may cause package delamination, formation of voids, or the phenomenon known as "popcorning"—an explosive cracking due to steam expansion. These failures compromise the device's mechanical and electrical reliability, potentially leading to open circuits or shorts.[3] MSL ratings apply specifically to moisture-sensitive devices (MSDs), which are defined as electronic components encapsulated in plastic or organic materials that exhibit measurable moisture uptake and risk of reflow-induced damage, distinguishing them from non-sensitive devices that have unlimited floor life and require no special handling. This system primarily targets surface-mount components, such as ball grid arrays (BGAs) and quad flat no-leads (QFNs), where thin packages exacerbate absorption risks, whereas hermetic or non-plastic packages are generally exempt.Importance in Electronics Manufacturing
Moisture absorption in electronic components, particularly plastic-encapsulated semiconductors, poses significant risks during high-temperature processes like reflow soldering, where absorbed water vaporizes rapidly, generating internal pressures that can exceed the mechanical strength of the package.[4] This pressure buildup often results in failures such as cracking of the molding compound, delamination at interfaces between the die and package, or lifting of wire bonds, compromising electrical connectivity and structural integrity.[5] These defects, commonly known as "popcorning," arise when vapor pressure surpasses the package's tensile strength, leading to explosive-like damage that renders components unusable.[4] In electronics manufacturing, unmanaged moisture sensitivity drastically lowers assembly yields by inducing immediate failures during soldering, necessitating costly rework or scrapping of boards, while also undermining long-term device reliability in diverse applications.[4] For instance, in consumer electronics exposed to humid environments, latent moisture can accelerate degradation over time, increasing the likelihood of intermittent failures; similarly, in automotive and aerospace systems, where reliability is paramount, such issues can lead to systemic malfunctions under thermal cycling or vibration.[5] The transition to lead-free soldering mandated by the 2006 RoHS directive exacerbated these challenges, as higher reflow temperatures (up to 260°C) intensified moisture vaporization, often requiring MSL requalification and resulting in downgraded sensitivity ratings for many components.[6] The economic consequences of moisture-induced failures are substantial, encompassing production losses, warranty claims, and repair expenses.[7] Safety implications are equally critical, as field failures in humid conditions—such as in portable devices or vehicular electronics—can precipitate hazardous malfunctions, including short circuits or loss of control in safety-critical systems.[5] Thus, MSL classification serves as an essential preventive measure to mitigate these risks and ensure robust manufacturing processes.[4]Classification System
MSL Levels
The moisture sensitivity levels (MSL) are a standardized hierarchical classification system ranging from 1 (least sensitive) to 6 (most sensitive), used to categorize nonhermetic surface-mount devices based on their vulnerability to moisture-induced damage during reflow soldering.[1] This system, established by IPC/JEDEC, ensures components can withstand specific preconditioning exposures without exhibiting failures such as delamination, cracking, or voids after multiple reflow cycles. Each level corresponds to a defined floor life—the maximum allowable exposure time to ambient conditions before processing—under controlled temperature and relative humidity (RH) thresholds, reflecting the device's moisture absorption tolerance. As of December 2022, these are defined in IPC/JEDEC J-STD-020F. The classification begins with MSL 1, which indicates unlimited floor life at ≤30°C/85% RH, suitable for devices with minimal moisture uptake that pass severe preconditioning without damage. Higher levels denote increasing sensitivity: MSL 2 allows 1 year at ≤30°C/60% RH; MSL 2a permits 4 weeks under the same conditions; MSL 3 supports 168 hours; MSL 4 allows 72 hours; MSL 5 accommodates 48 hours; and MSL 5a limits exposure to 24 hours, all at ≤30°C/60% RH. MSL 6 represents the highest sensitivity, with floor life restricted to the time on label (TOL) specified by the manufacturer at ≤30°C/60% RH, often requiring immediate processing or dry storage with potential baking.[1] Assignment to an MSL is determined through qualification testing, where devices undergo a soak period as defined in the standard for the proposed level (e.g., the specified preconditioning soak time), followed by three simulated reflow cycles; if the device passes without observable defects, it is classified at that level, while failure prompts testing at the next higher (more sensitive) level.[1]| MSL Level | Floor Life (at ≤30°C/60% RH unless noted) | Sensitivity Description |
|---|---|---|
| 1 | Unlimited (at ≤30°C/85% RH) | Least sensitive; no dry packing required. |
| 2 | 1 year | Low sensitivity; standard dry packing. |
| 2a | 4 weeks | Moderate sensitivity; enhanced monitoring needed. |
| 3 | 168 hours | Higher sensitivity; limited exposure. |
| 4 | 72 hours | Significant sensitivity; short handling window. |
| 5 | 48 hours | Very high sensitivity; requires careful control. |
| 5a | 24 hours | Extreme sensitivity within level 5 category. |
| 6 | Time on Label (TOL) | Most sensitive; manufacturer-specific handling mandatory. |
Floor Life Specifications
Floor life, also known as moisture sensitivity floor life, refers to the allowable time period after removal of a moisture-sensitive device from its moisture barrier bag (MBB), dry storage, or dry bake, and before the solder reflow process, during which the device's moisture absorption must not exceed safe limits to prevent damage during reflow soldering.[8] This period defines the safe handling window in ambient conditions, with the clock starting upon MBB removal, and it can be reset through appropriate drying processes to restore the full floor life duration. As of April 2018, these are detailed in IPC/JEDEC J-STD-033D, which references J-STD-020 for classifications. The standard ambient conditions for floor life exposure across all moisture sensitivity levels (MSL) are defined as ≤30°C and 60% relative humidity (RH), though some levels permit higher humidity thresholds.[8] Floor life specifications vary by MSL, providing quantitative limits based on the device's sensitivity to moisture-induced failures, such as package delamination or popcorning.[8] These durations ensure devices remain processable without exceeding critical moisture saturation levels. The following table summarizes the floor life for each MSL under standard conditions:| MSL Level | Floor Life (at ≤30°C/60% RH) | Notes |
|---|---|---|
| 1 | Unlimited | Also unlimited at ≤30°C/85% RH |
| 2 | 1 year | - |
| 2a | 4 weeks | - |
| 3 | 168 hours (7 days) | - |
| 4 | 72 hours (3 days) | - |
| 5 | 48 hours | - |
| 5a | 24 hours | - |
| 6 | Time on Label (TOL) | Manufacturer-specified; often requires baking before use and reflow within TOL |
Testing and Qualification
Preconditioning Procedures
The preconditioning procedures for moisture sensitivity level (MSL) qualification follow the standardized sequence defined in IPC/JEDEC J-STD-020 to simulate the cumulative effects of storage, handling, and reflow soldering on nonhermetic surface-mount devices. This unbiased process ensures components are exposed to accelerated environmental conditions equivalent to worst-case field scenarios before assessing potential damage.[9] The procedure commences with a dry bake to eliminate residual moisture, typically conducted at 125°C for a minimum of 24 hours in a controlled oven. This step is followed by the moisture absorption phase, or soak, where devices are placed in an environmental chamber under specific temperature and relative humidity (RH) conditions tailored to the MSL level under evaluation. Soak durations are derived from the device's floor life specifications plus a default 24-hour manufacturer exposure time (MET), using activation energy models to equate accelerated lab exposure to real-world conditions. For instance, MSL Level 1 devices undergo a soak of 168 hours at 85°C/85% RH, while MSL Level 2 requires 168 hours at 85°C/60% RH, and higher-sensitivity levels like MSL 3 use 192 hours at 30°C/60% RH to reflect shorter allowable floor lives.[9][10] Following the soak, within 15 minutes to 4 hours to prevent moisture desorption, the devices experience three cycles of simulated reflow soldering in a convection oven to mimic surface-mount assembly. Reflow profiles are governed by package volume and alloy type; for lead-free processes on packages greater than 1.6 mm thick, the peak temperature reaches 260°C, with liquidus at 217°C held for 60–150 seconds. Between cycles, a minimum of 5 minutes and maximum of 60 minutes elapses to allow partial recovery.[9][11] Environmental chambers for soaking must maintain precise control, such as ±2°C and ±3% RH, with devices oriented live-bug up and monitored via data loggers. Moisture uptake is verified by pre- and post-soak weighing of representative samples, targeting weight gains of 0.1–0.5% for typical plastic packages to confirm saturation levels. Reflow equipment includes full-convection ovens with thermocouple attachments per JEP140 for accurate temperature profiling at the device center. These steps collectively determine the MSL rating by exposing devices to equivalent moisture loads across levels.[9][12]| MSL Level | Floor Life (at ≤30°C/60% RH unless noted) | Representative Soak Condition | Soak Duration |
|---|---|---|---|
| 1 | Unlimited (≤30°C/85% RH) | 85°C/85% RH | 168 hours |
| 2 | 1 year | 85°C/60% RH | 168 hours |
| 2a | 4 weeks | 30°C/60% RH | 696 hours |
| 3 | 168 hours | 30°C/60% RH | 192 hours |
| 4 | 72 hours | 30°C/60% RH | 96 hours |
| 5 | 48 hours | 30°C/60% RH | 72 hours |
| 5a | 24 hours | 30°C/60% RH | 48 hours |
| 6 | Time on label | As specified | As specified |
Failure Criteria and Evaluation
After preconditioning and simulated reflow soldering, components undergo rigorous evaluation to detect moisture-induced damage such as cracks, delamination, or functional degradation, ensuring compliance with moisture sensitivity level (MSL) ratings. This assessment typically involves a combination of non-destructive and destructive inspection methods to identify failures that could compromise device reliability during assembly. Inspection begins with visual examination using an optical microscope at 40X magnification (or higher, such as 100X or SEM for detailed analysis) to check for external cracks, package deformation, warpage, swelling, or bulging visible to the naked eye. Electrical testing is conducted before and after the three reflow cycles, verifying functionality against the manufacturer's datasheet specifications at room temperature; any deviation resulting in test failure indicates moisture-related damage.[2] For internal defects like voids, popcorn cracks, or delamination, non-destructive techniques such as C-mode scanning acoustic microscopy (CSAM) are employed to detect changes, with cross-sectioning of select samples providing confirmatory analysis by polishing and examining for cracks intersecting bond wires, lead fingers, or extending more than two-thirds of the distance to the package exterior. Pass/fail thresholds are defined strictly to ensure no compromise in package integrity: a component passes if there are no external cracks, no electrical failures, no internal cracks meeting the specified criteria, and delamination limited to less than 10% change on wire bonding surfaces, die attach regions, or laminate interfaces (with no delamination on the active die side). Package warpage or swelling is acceptable only if it meets coplanarity or standoff specifications per JESD22-B112 or JESD22-B108; otherwise, visible deformation after reflow constitutes failure.[2] If delamination occurs without cracking, additional reliability testing under JESD22-A113 or JESD47 is required to assess long-term effects. These thresholds apply to a sample of 11 to 22 units per MSL level; failure of even one device results in rejection at that level. Reclassification of MSL occurs when initial testing fails at a lower numerical level (e.g., Level 1) but passes at a higher one (e.g., Level 2 or 3), assigning the highest passing level while requiring dry packing per J-STD-033 for moisture-sensitive devices. Improvements in classification (e.g., to a lower numerical level) are permitted only if damage responses do not exceed those from the original rating, limited to one level without additional reliability qualification, except for Level 1, which demands further testing. If failures persist across levels, failure analysis is conducted to identify root causes and potentially reevaluate the device type.Handling and Mitigation
Storage and Packaging Requirements
Moisture-sensitive devices (MSDs) must be stored and transported in protective packaging to minimize moisture absorption prior to assembly, ensuring compliance with industry standards that prevent damage during subsequent reflow soldering processes.[14] The primary packaging method involves sealing MSDs in moisture barrier bags (MBBs), which are constructed from materials meeting MIL-PRF-81705 Type I specifications, exhibiting a water vapor transmission rate (WVTR) of ≤0.031 g/m² per 24 hours at 40°C as tested per ASTM F1249. These bags are heat-sealed, often with light air evacuation, to create a low-humidity environment inside. Accompanying each MBB are desiccants compliant with MIL-D-3464 Type II, which are dustless and noncorrosive, placed in sufficient quantity based on bag surface area to maintain dryness—calculated as U = (0.304 × M × WVTR × A) / D units, where M is the desired shelf life in months, WVTR is in g/m²/24 h, A is the internal bag area in m², and D is the desiccant capacity in grams at 10% RH and 25°C (typically 1.40 g/unit). Additionally, humidity indicator cards (HICs) are included within the MBBs to monitor internal relative humidity (RH); these cards feature indicator spots at 5%, 10%, and 60% RH thresholds, changing color from blue (dry) to pink (humid) when exposed above the respective levels, allowing users to assess package integrity at 23 ± 5°C. For devices requiring finer low-RH monitoring, HICs with 5%, 10%, and 15% spots are commonly used in conjunction with the standard to detect early moisture ingress.[14] Labeling on the MBBs and associated carriers, such as reels or trays, is mandatory to communicate handling needs and includes the device's MSL rating, floor life duration at ≤30°C/60% RH, and specific instructions like "Do not open until ready to use" or baking advisories if the HIC indicates exposure above 10% RH for MSL levels 2a through 5a. These labels, often in the form of a Moisture-Sensitive Identification Label (MSID) or Caution Label, must be affixed to the lowest-level shipping container or directly on the MBB exterior, with details such as the packing date code for traceability. Floor life, which begins upon opening the MBB, is thus clearly delineated to guide users on exposure limits before assembly.[14] The sealed shelf life of packaged MSDs is typically 12 months from the date of packing when stored at <40°C and <90% RH, after which the integrity of the dry package should be reverified using the HIC or repackaged if necessary; this duration applies to most MSL levels, with date codes on labels enabling ongoing tracking to ensure devices remain within specifications until use.[14]Baking and Recovery Methods
Baking serves as a critical recovery process for moisture-sensitive devices (MSDs) that have exceeded their specified floor life exposure, allowing the removal of absorbed moisture to prevent defects such as delamination or cracking during reflow soldering. According to JEDEC J-STD-033D (April 2018), baking involves controlled heating in a dry environment (typically <5% relative humidity) to drive out moisture without damaging the component. The process resets the device's floor life, enabling it to be repackaged and handled under standard conditions.[14] The primary baking parameters outlined in J-STD-033D depend on the device's MSL classification and package thickness, with common recommendations including 125°C for 24 to 48 hours for packages thicker than 2.0 mm at higher MSL levels (e.g., MSL 5a), or shorter durations for thinner packages (e.g., 8 hours for ≤1.4 mm at MSL 3 exceeding floor life by >72 hours). For lower temperatures to accommodate sensitive materials, 90°C can be used for extended periods, such as 240 hours (10 days) for thicker packages (>2.0 mm) at MSL 5, ensuring equivalent moisture removal. These durations account for MSL-specific sensitivities, where higher levels require longer bakes to achieve sufficient drying due to greater moisture absorption potential. Verification of effective drying is achieved through methods like monitoring weight loss (targeting <0.002% reduction per JESD22-A120) or retesting via preconditioning procedures to confirm no moisture-induced failures occur.[14] Recovery rules under J-STD-033D stipulate a full reset of the floor life upon successful baking, provided the process is completed within the time windows specified for the exposure exceedance (e.g., within days of opening for MSL 4-5a). The device must then be immediately vacuum-sealed in a moisture barrier bag with fresh desiccant to maintain the reset state, effectively restoring its original handling limits plus an additional 72 hours in some cases. For MSL 5 and 6 devices, partial recovery is not permitted; a complete bake is mandatory before any further processing or reflow, as these levels exhibit the highest sensitivity to residual moisture.[14] Precautions during baking are essential to avoid unintended damage. Overbaking must be prevented by limiting cumulative exposure at temperatures above 90°C to 96 hours, as prolonged heat can lead to oxidation of leads or degradation of internal materials like adhesives. Manufacturers recommend consulting device suppliers before exceeding 125°C, and using dedicated high-temperature baking trays or racks for components in reels or trays to ensure even airflow and prevent mechanical stress from low-temperature carriers. Proper oven calibration and monitoring of environmental conditions further mitigate risks.[14]Standards and Applications
Key Standards (JEDEC/IPC)
The primary standard for moisture/reflow sensitivity classification of nonhermetic surface mount devices (SMDs) is IPC/JEDEC J-STD-020, which defines procedures to identify the classification level of devices sensitive to moisture-induced stress during reflow soldering. The latest revision, J-STD-020F released in November 2022, expands coverage to include lead-free assemblies and bottom termination components, such as ball grid arrays (BGAs), while maintaining the core moisture sensitivity levels (MSL 1 through 6) based on floor life and preconditioning soak times at specified humidity levels.[15] Complementing classification, IPC/JEDEC J-STD-033 establishes standardized methods for handling, packing, shipping, and using moisture/reflow sensitive surface mount devices (MSDs) to prevent moisture absorption and related failures. The current revision, J-STD-033D from March 2018, includes detailed appendices on baking schedules tailored to MSL ratings and package thickness, as well as requirements for labeling dry packages with humidity indicator cards and barcodes to track exposure conditions. These joint standards originated in the 1990s with JEDEC's JESD22-A112, published in 1994, which first outlined moisture-induced stress testing for plastic SMDs but was superseded by the collaborative IPC/JEDEC J-STD-020A in 1999 to consolidate industry practices.[16] Subsequent revisions in the 2000s, including J-STD-020C in 2004 and J-STD-033B in 2005, incorporated updates for RoHS compliance by addressing higher reflow temperatures in lead-free processes, ensuring broader applicability to modern electronics manufacturing.Industry Implementation and Compliance
In the electronics supply chain, adoption of moisture sensitivity level (MSL) practices begins with clear component marking on packaging to facilitate proper handling and traceability. Manufacturers affix MSL ratings directly to moisture barrier bags and shipping containers via dry pack labels, often including an MSID label, alongside humidity indicator cards and desiccants, as required for compliance with industry handling protocols. This marking ensures that downstream partners, from distributors to assemblers, can immediately identify sensitivity levels and associated floor life limits without relying solely on datasheets.[17] Supplier audits play a critical role in enforcing MSL adoption, evaluating vendors' adherence to dry packing, labeling, and storage procedures to prevent moisture ingress during transit. These audits, aligned with standards like IPC-A-610 for assembly quality, verify that suppliers maintain documented processes for MSL-rated parts.[18][19] Furthermore, integration of MSL tracking into enterprise resource planning (ERP) systems enables real-time monitoring of floor life, with software modules assigning humidity exposure limits by part number and alerting on exceeded thresholds via barcode or RFID scanning. For instance, specialized inventory tools track component reel locations, baking events, and ambient exposure to automate compliance across global operations.[20] Key challenges in MSL implementation arise from environmental variations across global supply chains, where higher ambient humidity in regions like Southeast Asia can accelerate moisture absorption and shorten effective floor life compared to standardized 30°C/60% RH conditions. Counterfeit components exacerbate this issue, frequently arriving without authentic MSL markings, datasheets, or moisture-sensitive packaging such as desiccants and indicator cards, leading to undetected risks during reflow soldering. Moreover, the introduction of new materials, such as advanced epoxy molding compounds (EMCs), necessitates periodic MSL rating updates to account for enhanced delamination resistance, as seen in formulations designed for MSL 1 performance under 85°C/85% RH preconditioning.[21][22][23] To address these challenges, best practices emphasize comprehensive training for assembly handlers through certified programs that cover moisture control, ESD prevention, and component damage avoidance. Automated baking ovens, calibrated for precise 90–125°C cycles lasting 24–48 hours, streamline recovery of exposed parts by integrating with tracking systems to trigger drying based on exposure data, ensuring consistent moisture removal without manual oversight. Finally, achieving compliance certifications like IPC-A-610 validates assembly processes by confirming adherence to criteria for handling MSL-sensitive devices, including defect-free solder joints free from moisture-induced voids.[24][25][25]References
- https://nepp.[nasa](/page/NASA).gov/DocUploads/F9103397-759A-4BBA-AD646D32C0A133D7/MOISTURE-LEVEL-TESTING-REPORT-Final.pdf