Recent from talks
Contribute something to knowledge base
Content stats: 0 posts, 0 articles, 0 media, 0 notes
Members stats: 0 subscribers, 0 contributors, 0 moderators, 0 supporters
Subscribers
Supporters
Contributors
Moderators
Hub AI
Image intensifier AI simulator
(@Image intensifier_simulator)
Hub AI
Image intensifier AI simulator
(@Image intensifier_simulator)
Image intensifier
An image intensifier or image intensifier tube is a vacuum tube device for increasing the intensity of available light in an optical system to allow use under low-light conditions, such as at night, to facilitate visual imaging of low-light processes, such as fluorescence of materials in X-rays or gamma rays (X-ray image intensifier), or for conversion of non-visible light sources, such as near-infrared or short wave infrared to visible. They operate by converting photons of light into electrons, amplifying the electrons (usually with a microchannel plate), and then converting the amplified electrons back into photons for viewing. They are used in devices such as night-vision goggles.
Image intensifier tubes (IITs) are optoelectronic devices that allow many devices, such as night vision devices and medical imaging devices, to function. They convert low levels of light from various wavelengths into visible quantities of light at a single wavelength.
Image intensifiers convert low levels of light photons into electrons, amplify those electrons, and then convert the electrons back into photons of light. Photons from a low-light source enter an objective lens which focuses an image into a photocathode. The photocathode releases electrons via the photoelectric effect as the incoming photons hit it. The electrons are accelerated through a high-voltage potential into a microchannel plate (MCP). Each high-energy electron that strikes the MCP causes the release of many electrons from the MCP in a process called secondary cascaded emission. The MCP is made up of thousands of tiny conductive channels, tilted at an angle away from normal to encourage more electron collisions and thus enhance the emission of secondary electrons in a controlled Electron avalanche.
All the electrons move in a straight line due to the high-voltage difference across the plates, which preserves collimation, and where one or two electrons entered, thousands may emerge. A separate (lower) charge differential accelerates the secondary electrons from the MCP until they hit a phosphor screen at the other end of the intensifier, which releases a photon for every electron. The image on the phosphor screen is focused by an eyepiece lens. The amplification occurs at the microchannel plate stage via its secondary cascaded emission. The phosphor is usually green because the human eye is more sensitive to green than other colors and because historically the original material used to produce phosphor screens produced green light (hence the soldiers' nickname 'green TV' for image intensification devices).
The development of image intensifier tubes began during the 20th century, with continuous development since inception.
The idea of an image tube was first proposed by G. Holst and H. De Boer in 1928, in the Netherlands [1], but early attempts to create one were not successful. It was not until 1934 that Holst, working for Philips, created the first successful infrared converter tube. This tube consisted of a photocathode in proximity to a fluorescent screen. Using a simple lens, an image was focused on the photocathode and a potential difference of several thousand volts was maintained across the tube, causing electrons dislodged from the photocathode by photons to strike the fluorescent screen. This caused the screen to light up with the image of the object focused onto the screen, however the image was non-inverting. With this image converter type tube, it was possible to view infrared light in real time, for the first time.
Development continued in the US as well during the 1930s and mid-1930, the first inverting image intensifier was developed at RCA. This tube used an electrostatic inverter to focus an image from a spherical cathode onto a spherical screen. (The choice of spheres was to reduce off-axial aberrations.) Subsequent development of this technology led directly to the first Generation 0 image intensifiers which were used by the military during World War II to allow vision at night with infrared lighting for both shooting and personal night vision. The first military night vision device was introduced by the German army[citation needed] as early as 1939, developed since 1935. Early night vision devices based on these technologies were used by both sides in World War II.
Unlike later technologies, early Generation 0 night vision devices were unable to significantly amplify the available ambient light and so, to be useful, required an infrared source. These devices used an S1 photocathode or "silver-oxygen-caesium" photocathode, discovered in 1930, which had a sensitivity of around 60 μA/lm (Microampere per Lumen) and a quantum efficiency of around 1% in the ultraviolet region and around 0.5% in the infrared region. Of note, the S1 photocathode had sensitivity peaks in both the infrared and ultraviolet spectrum and with sensitivity over 950 nm was the only photocathode material that could be used to view infrared light above 950 nm.
Image intensifier
An image intensifier or image intensifier tube is a vacuum tube device for increasing the intensity of available light in an optical system to allow use under low-light conditions, such as at night, to facilitate visual imaging of low-light processes, such as fluorescence of materials in X-rays or gamma rays (X-ray image intensifier), or for conversion of non-visible light sources, such as near-infrared or short wave infrared to visible. They operate by converting photons of light into electrons, amplifying the electrons (usually with a microchannel plate), and then converting the amplified electrons back into photons for viewing. They are used in devices such as night-vision goggles.
Image intensifier tubes (IITs) are optoelectronic devices that allow many devices, such as night vision devices and medical imaging devices, to function. They convert low levels of light from various wavelengths into visible quantities of light at a single wavelength.
Image intensifiers convert low levels of light photons into electrons, amplify those electrons, and then convert the electrons back into photons of light. Photons from a low-light source enter an objective lens which focuses an image into a photocathode. The photocathode releases electrons via the photoelectric effect as the incoming photons hit it. The electrons are accelerated through a high-voltage potential into a microchannel plate (MCP). Each high-energy electron that strikes the MCP causes the release of many electrons from the MCP in a process called secondary cascaded emission. The MCP is made up of thousands of tiny conductive channels, tilted at an angle away from normal to encourage more electron collisions and thus enhance the emission of secondary electrons in a controlled Electron avalanche.
All the electrons move in a straight line due to the high-voltage difference across the plates, which preserves collimation, and where one or two electrons entered, thousands may emerge. A separate (lower) charge differential accelerates the secondary electrons from the MCP until they hit a phosphor screen at the other end of the intensifier, which releases a photon for every electron. The image on the phosphor screen is focused by an eyepiece lens. The amplification occurs at the microchannel plate stage via its secondary cascaded emission. The phosphor is usually green because the human eye is more sensitive to green than other colors and because historically the original material used to produce phosphor screens produced green light (hence the soldiers' nickname 'green TV' for image intensification devices).
The development of image intensifier tubes began during the 20th century, with continuous development since inception.
The idea of an image tube was first proposed by G. Holst and H. De Boer in 1928, in the Netherlands [1], but early attempts to create one were not successful. It was not until 1934 that Holst, working for Philips, created the first successful infrared converter tube. This tube consisted of a photocathode in proximity to a fluorescent screen. Using a simple lens, an image was focused on the photocathode and a potential difference of several thousand volts was maintained across the tube, causing electrons dislodged from the photocathode by photons to strike the fluorescent screen. This caused the screen to light up with the image of the object focused onto the screen, however the image was non-inverting. With this image converter type tube, it was possible to view infrared light in real time, for the first time.
Development continued in the US as well during the 1930s and mid-1930, the first inverting image intensifier was developed at RCA. This tube used an electrostatic inverter to focus an image from a spherical cathode onto a spherical screen. (The choice of spheres was to reduce off-axial aberrations.) Subsequent development of this technology led directly to the first Generation 0 image intensifiers which were used by the military during World War II to allow vision at night with infrared lighting for both shooting and personal night vision. The first military night vision device was introduced by the German army[citation needed] as early as 1939, developed since 1935. Early night vision devices based on these technologies were used by both sides in World War II.
Unlike later technologies, early Generation 0 night vision devices were unable to significantly amplify the available ambient light and so, to be useful, required an infrared source. These devices used an S1 photocathode or "silver-oxygen-caesium" photocathode, discovered in 1930, which had a sensitivity of around 60 μA/lm (Microampere per Lumen) and a quantum efficiency of around 1% in the ultraviolet region and around 0.5% in the infrared region. Of note, the S1 photocathode had sensitivity peaks in both the infrared and ultraviolet spectrum and with sensitivity over 950 nm was the only photocathode material that could be used to view infrared light above 950 nm.
