Heart sounds are the noises generated by the beating heart and the resultant flow of blood through it. Specifically, the sounds reflect the turbulence created when the heart valves snap shut. In cardiac auscultation, an examiner may use a stethoscope to listen for these unique and distinct sounds that provide important auditory data regarding the condition of the heart.

In healthy adults, there are two normal heart sounds, often described as a lub and a dub that occur in sequence with each heartbeat. These are the first heart sound (S1) and second heart sound (S2), produced by the closing of the atrioventricular valves and semilunar valves, respectively. In addition to these normal sounds, a variety of other sounds may be present including heart murmurs, adventitious sounds, and gallop rhythms S3 and S4.

Heart murmurs are generated by turbulent flow of blood and a murmur to be heard as turbulent flow must require pressure difference of at least 30 mm of Hg between the chambers and the pressure dominant chamber will outflow the blood to non-dominant chamber in diseased condition which leads to Left-to-right shunt or Right-to-left shunt based on the pressure dominance. Turbulence may occur inside or outside the heart; if it occurs outside the heart then the turbulence is called bruit or vascular murmur. Murmurs may be physiological (benign) or pathological (abnormal). Abnormal murmurs can be caused by stenosis restricting the opening of a heart valve, resulting in turbulence as blood flows through it. Abnormal murmurs may also occur with valvular insufficiency (regurgitation), which allows backflow of blood when the incompetent valve closes with only partial effectiveness. Different murmurs are audible in different parts of the cardiac cycle, depending on the cause of the murmur.

Primary heart sounds

[edit]
Diagram showing relations of opened heart to front of thoracic wall. Ant. Anterior segment of tricuspid valve. A O. Aorta. A.P. Anterior papillary muscle. In. Innominate artery. L.C.C. Left common carotid artery. L.S. Left subclavian artery. L.V. Left ventricle. P.A. Pulmonary artery. R.A. Right atrium. R.V. Right ventricle. V.S. Ventricular septum.

Normal heart sounds are associated with heart valves closing:

First heart sound

[edit]

The first heart sound, or S1, forms the "lub" of "lub-dub" and is composed of components M1 (mitral valve closure) and T1 (tricuspid valve closure). Normally M1 precedes T1 slightly. It is caused by the closure of the atrioventricular valves, i.e. tricuspid and mitral (bicuspid), at the beginning of ventricular contraction, or systole. When the ventricles begin to contract, so do the papillary muscles in each ventricle. The papillary muscles are attached to the cusps or leaflets of the tricuspid and mitral valves via chordae tendineae (heart strings). When the papillary muscles contract, the chordae tendineae become tense and thereby prevent the backflow of blood into the lower pressure environment of the atria. The chordae tendineae act a bit like the strings on a parachute, and allow the leaflets of the valve to balloon up into the atria slightly, but not so much as to evert the cusp edges and allow backflow of blood. It is the pressure created from ventricular contraction that closes the valve, not the papillary muscles themselves. The contraction of the ventricle begins just prior to AV valves closing and prior to the opening of the semilunar valves. The sudden tensing of the chordae tendineae and the squeezing of the ventricles against closed semilunar valves, send blood rushing back toward the atria, and the parachute-like valves catch the rush of blood in their leaflets causing the valve to snap shut. The S1 sound results from reverberation within the blood associated with the sudden block of flow reversal by the valves. The delay of T1 even more than normally causes the split S1 which is heard in a right bundle branch block.[1]

Second heart sound

[edit]

The second heart sound, or S2, forms the "dub" of "lub-dub" and is composed of components A2 (aortic valve closure) and P2 (pulmonary valve closure). Normally A2 precedes P2 especially during inspiration where a split of S2 can be heard. It is caused by the closure of the semilunar valves (the aortic valve and pulmonary valve) at the end of ventricular systole and the beginning of ventricular diastole. As the left ventricle empties, its pressure falls below the pressure in the aorta. Aortic blood flow quickly reverses back toward the left ventricle, catching the pocket-like cusps of the aortic valve, and is stopped by aortic valve closure. Similarly, as the pressure in the right ventricle falls below the pressure in the pulmonary artery, the pulmonary valve closes. The S2 sound results from reverberation within the blood associated with the sudden block of flow reversal.[1]

Splitting of S2, also known as physiological split, normally occurs during inhalation because the decrease in intrathoracic pressure increases the time needed for pulmonary pressure to exceed that of the right ventricular pressure. A widely split S2 can be associated with several different cardiovascular conditions, and the split is sometimes wide and variable whereas, sometimes wide and fixed. The wide and variable split occurs in Right bundle branch block, pulmonary stenosis, pulmonary hypertension and ventricular septal defects. The wide and fixed splitting of S2 occurs in atrial septal defect. Pulmonary S2 (P2) will be accentuated (loud P2) in pulmonary hypertension and pulmonary embolism. S2 becomes softer in aortic stenosis.[1]

Extra heart sounds

[edit]

The rarer extra heart sounds form gallop rhythms and are heard in both normal and abnormal situations.[1]

Third heart sound

[edit]

The third heart sound, or S3 is rarely heard, and is also called a protodiastolic gallop, ventricular gallop, or informally the "Kentucky" gallop as an onomatopoeic reference to the rhythm and stress of S1 followed by S2 and S3 together (S1=Ken; S2=tuck; S3=y).[2]

"lub-dub-ta" or "slosh-ing-in" If new, indicates heart failure or volume overload.[citation needed]

It occurs at the beginning of diastole after S2 and is lower in pitch than S1 or S2 as it is not of valvular origin. The third heart sound is benign in youth, some trained athletes, and sometimes in pregnancy but if it re-emerges later in life it may signal cardiac problems, such as a failing left ventricle as in dilated congestive heart failure (CHF). S3 is thought to be caused by the oscillation of blood back and forth between the walls of the ventricles initiated by blood rushing in from the atria. The reason the third heart sound does not occur until the middle third of diastole is probably that during the early part of diastole, the ventricles are not filled sufficiently to create enough tension for reverberation.[1]

It may also be a result of tensing of the chordae tendineae during rapid filling and expansion of the ventricle. In other words, an S3 heart sound indicates increased volume of blood within the ventricle. An S3 heart sound is best heard with the bell-side of the stethoscope (used for lower frequency sounds). A left-sided S3 is best heard in the left lateral decubitus position and at the apex of the heart, which is normally located in the 5th left intercostal space at the midclavicular line. A right-sided S3 is best heard at the lower left sternal border. The way to distinguish between left and right-sided S3 is to observe whether it increases in intensity with inhalation or exhalation. A right-sided S3 will increase on inhalation, while a left-sided S3 will increase on exhalation.[1]

S3 can be a normal finding in young patients but is generally pathologic over the age of 40. The most common cause of pathologic S3 is congestive heart failure.[1]

Fourth heart sound

[edit]

The fourth heart sound, or S4 when audible in an adult is called a presystolic gallop or atrial gallop. This gallop is produced by the sound of blood being forced into a stiff or hypertrophic ventricle.[1]

"ta-lub-dub" or "a-stiff-wall"

It is a sign of a pathologic state, usually a failing or hypertrophic left ventricle, as in systemic hypertension, severe valvular aortic stenosis, and hypertrophic cardiomyopathy. The sound occurs just after atrial contraction at the end of diastole and immediately before S1, producing a rhythm sometimes referred to as the "Tennessee" gallop where S4 represents the "Ten-" syllable.[2] It is best heard at the cardiac apex with the patient in the left lateral decubitus position and holding their breath. The combined presence of S3 and S4 is a quadruple gallop, also known as the "Hello-Goodbye" gallop. At rapid heart rates, S3 and S4 may merge to produce a summation gallop, sometimes referred to as S7.[1]

Atrial contraction must be present for production of an S4. It is absent in atrial fibrillation and in other rhythms in which atrial contraction does not precede ventricular contraction.[1]

Murmurs

[edit]
Phonocardiogram from normal and abnormal heart sounds.

Heart murmurs are produced as a result of turbulent flow of blood strong enough to produce audible noise. They are usually heard as a whooshing sound. The term murmur only refers to a sound believed to originate within blood flow through or near the heart; rapid blood velocity is necessary to produce a murmur. Most heart problems do not produce any murmur and most valve problems also do not produce an audible murmur.[3]

Murmurs can be heard in many situations in adults without major congenital heart abnormalities:[3]

  • Regurgitation through the mitral valve is by far the most commonly heard murmur, producing a pansystolic/holosystolic murmur which is sometimes fairly loud to a practiced ear, even though the volume of regurgitant blood flow may be quite small. Yet, though obvious using echocardiography visualization, probably about 20% of cases of mitral regurgitation do not produce an audible murmur.[3]
  • Stenosis of the aortic valve is typically the next most common heart murmur, a systolic ejection murmur. This is more common in older adults or in those individuals having a two-leaflet, not a three-leaflet, aortic valve.[citation needed]
  • Regurgitation through the aortic valve, if marked, is sometimes audible to a practiced ear with high quality, especially electronically amplified, stethoscope. Generally, this is a very rarely heard murmur, even though aortic valve regurgitation is not so rare. Aortic regurgitation, though obvious using echocardiography visualization, usually does not produce an audible murmur.[citation needed]
  • Stenosis of the mitral valve, if severe, also rarely produces an audible, low frequency soft rumbling murmur, best recognized by a practiced ear using high quality, especially electronically amplified, stethoscope.
  • Other audible murmurs are associated with abnormal openings between the left ventricle and right heart or from the aortic or pulmonary arteries back into a lower pressure heart chamber.
Gradations of Murmurs[1] (Defined based on use of an acoustic, not a high-fidelity amplified electronic stethoscope)
Grade Description
Grade 1 Very faint, heard only after listener has "tuned in"; may not be heard in all positions. Only heard if the patient "bears down" or performs the Valsalva maneuver.
Grade 2 Quiet, but heard immediately after placing the stethoscope on the chest.
Grade 3 Moderately loud.
Grade 4 Loud, with palpable thrill (a tremor or vibration felt on palpation)[4]
Grade 5 Very loud, with thrill. May be heard when stethoscope is partly off the chest.
Grade 6 Very loud, with thrill. May be heard with stethoscope entirely off the chest.

Though several different cardiac conditions can cause heart murmurs, the murmurs can change markedly with the severity of the cardiac disease. An astute physician can sometimes diagnose cardiac conditions with some accuracy based largely on the murmur, related physical examination, and experience with the relative frequency of different heart conditions. However, with the advent of better quality and wider availability of echocardiography and other techniques, heart status can be recognized and quantified much more accurately than formerly possible with only a stethoscope, examination, and experience. Another advantage to the use of the echocardiogram is that the devices can be handheld.[5]

Effects of breathing

[edit]

Inhalation decreases intrathoracic pressure which allows more venous blood to return to the right heart (pulling blood into the right side of the heart via a vacuum-like effect). Therefore, right-sided heart murmurs generally increase in intensity with inhalation. The decreased (more negative) intrathoracic pressure has an opposite effect on the left side of the heart, making it harder for the blood to exit into circulation. Therefore, left-sided murmurs generally decrease in intensity during inhalation. Increasing venous blood return to the right side of the heart by raising a patient's legs to a 45-degree while lying supine produces similar effect which occurs during inhalation. Inhalation can also produce a non-pathological split S2 which will be heard upon auscultation.[citation needed]

With exhalation, the opposite haemodynamic changes occur: left-sided murmurs generally increase in intensity with exhalation.[citation needed]

Interventions that change murmurs

[edit]

There are a number of interventions that can be performed that alter the intensity and characteristics of abnormal heart sounds. These interventions can differentiate the different heart sounds to more effectively obtain a diagnosis of the cardiac anomaly that causes the heart sound.[citation needed]

Other abnormal sounds

[edit]

Clicks – Heart clicks are short, high-pitched sounds that can be appreciated with modern non-invasive imaging techniques.[citation needed]

Rubs – The pericardial friction rub can be heard in pericarditis, an inflammation of the pericardium, the sac surrounding the heart. This is a characteristic scratching, creaking, high-pitched sound emanating from the rubbing of both layers of inflamed pericardium. It is the loudest in systole, but can often be heard at the beginning and at the end of diastole. It is very dependent on body position and breathing, and changes from hour to hour.[citation needed]

Surface anatomy

[edit]

The aortic area, pulmonic area, tricuspid area and mitral area are areas on the surface of the chest where the heart is auscultated.[6] Heart sounds result from reverberation within the blood associated with the sudden block of flow reversal by the valves closing. Because of this, auscultation to determine function of a valve is usually not performed at the position of the valve, but at the position to where the sound waves reverberate.[citation needed]

Aortic valve (to aorta) right second intercostal space upper right sternal border
Pulmonary valve (to pulmonary trunk) left second intercostal space upper left sternal border
Erb's point Left third intercostal space left sternal border
Tricuspid valve (to right ventricle) left fourth, fifth intercostal spaces lower left sternal border
Mitral valve (to left ventricle) left fifth intercostal space left midclavicular line

Recording heart sounds

[edit]

Using electronic stethoscopes, it is possible to record heart sounds via direct output to an external recording device, such as a laptop or MP3 recorder. The same connection can be used to listen to the previously recorded auscultation through the stethoscope headphones, allowing for a more detailed study of murmurs and other heart sounds, for general research as well as evaluation of a particular patient's condition.[citation needed]

See also

[edit]

References

[edit]
[edit]
Revisions and contributorsEdit on WikipediaRead on Wikipedia
from Grokipedia
Heart sounds are the discrete auditory vibrations generated by the mechanical actions of the heart, primarily from the closure of its valves and the turbulent flow of blood through the cardiac chambers during each cycle of contraction (systole) and relaxation (diastole).[1] These sounds are typically assessed through auscultation using a stethoscope placed on the chest wall, allowing clinicians to evaluate heart function non-invasively.[1] In a healthy heart, two primary sounds are heard: the first heart sound (S1), often described as "lub," results from the synchronous closure of the mitral and tricuspid atrioventricular valves at the onset of ventricular systole, marking the beginning of blood ejection into the arteries.[2] The second heart sound (S2), known as "dub," occurs due to the closure of the semilunar valves (aortic and pulmonic) at the end of systole, signaling the start of ventricular filling in diastole.[2] These sounds may exhibit physiological splitting—S1 due to slight delays in right-sided valve closure and S2 varying with respiration as pulmonary vascular resistance changes—a normal variation that aids in distinguishing left and right heart contributions.[1] Beyond S1 and S2, additional heart sounds can occur under specific conditions. The third heart sound (S3) is a low-frequency vibration in early diastole, associated with rapid ventricular filling and potentially indicating volume overload or reduced compliance, as seen in heart failure.[3] The fourth heart sound (S4) arises from atrial contraction against a stiff ventricle in late diastole, often signaling hypertrophy or ischemia.[4] Abnormal sounds like clicks (from valve prolapse or stenosis) or opening snaps further point to structural issues.[1] Heart murmurs, which are prolonged swishing or whooshing noises from turbulent blood flow, represent a key category of abnormal sounds and may arise from valvular defects, septal anomalies, or increased flow states such as anemia or pregnancy.[5] Systolic murmurs occur between S1 and S2, while diastolic ones follow S2; their intensity, timing, location, and radiation provide diagnostic clues to underlying pathology.[6] Clinically, analyzing heart sounds is fundamental to cardiovascular examination, helping detect congenital defects, valvular diseases, cardiomyopathies, and other conditions early, often guiding further tests like echocardiography.[1] Abnormal findings, such as persistent murmurs, warrant investigation to prevent complications like heart failure or endocarditis.[7]

Overview and Physiology

Definition and Clinical Significance

Heart sounds are the audible vibrations generated by the closure of cardiac valves, myocardial contractions, and turbulent blood flow within the heart chambers and great vessels, which can be detected through chest auscultation using a stethoscope.[1][8] These acoustic phenomena arise during the cardiac cycle and provide key insights into cardiac function.[1] The systematic study of heart sounds began in 1819 when French physician René-Théophile-Hyacinthe Laennec published Traité de l'auscultation médiate, describing their characteristics following his invention of the stethoscope in 1816 to enable non-invasive listening to internal body sounds.[9] This innovation revolutionized clinical examination by allowing precise detection of cardiac acoustics without direct contact.[9] Clinically, heart sounds serve as a non-invasive diagnostic tool for identifying valvular disorders such as stenosis or regurgitation, heart failure indicated by extra sounds, and congenital defects like septal anomalies through characteristic murmurs and timing irregularities.[10][1] Their assessment often integrates with electrocardiography (ECG) to precisely time sounds relative to electrical events, enhancing accuracy in pinpointing abnormalities during systole or diastole.[11] The primary sounds, S1 and S2, form the basis for recognizing additional or abnormal components.[1] In a normal heart, these sounds produce a characteristic "lub-dub" rhythm, where the "lub" (S1) marks the onset of ventricular systole with atrioventricular valve closure, and the "dub" (S2) signals the beginning of diastole with semilunar valve closure.[12][13] This cadence reflects the alternating phases of contraction and relaxation essential for efficient blood circulation.[12]

Mechanisms of Sound Production

Heart sounds arise primarily from mechanical vibrations generated within the heart, including the closure and opening of cardiac valves, rapid deceleration of blood flow, and tensions in associated structures such as chordae tendineae and ventricular walls. These vibrations originate from the interaction between the heart's muscular contractions and the fluid dynamics of blood movement through the chambers and great vessels. The resulting acoustic energy is transmitted as pressure waves through the surrounding tissues, including the pericardium, lungs, and ultimately the chest wall, where it becomes audible upon auscultation; however, transmission can be attenuated by factors such as lung tissue interference or increased chest wall thickness.[1][14][15] The biomechanical basis of these sounds involves pressure gradients that drive blood flow across the valves and into the chambers, leading to sudden changes in velocity and direction that produce turbulence. This turbulence, combined with the elastic recoil of valve leaflets and chamber walls, generates oscillatory vibrations at audible frequencies typically ranging from 20 to 1000 Hz.[16] For instance, the abrupt closure of atrioventricular valves during ventricular contraction exemplifies how fluid-structure interactions amplify these vibrations into distinct sounds.[15][14] In alignment with the cardiac cycle, systolic sounds are predominantly produced during ventricular contraction, when pressure rises rapidly to eject blood, causing valve closures and associated vibrations. Diastolic sounds, in contrast, occur during ventricular relaxation, as blood flows from the atria into the ventricles driven by pressure gradients, potentially inducing additional oscillations in the valves and walls. This temporal linkage ensures that heart sounds provide a sonic correlate to the hemodynamic events of each phase.[1][15] The intensity of these sounds is modulated by several physiological factors, including the stiffness of valve leaflets, which determines the rapidity and force of closure; blood viscosity, which dampens turbulence in thicker fluids; and the thickness of the chest wall, which attenuates transmission of vibrations to the surface. Stiffer valves, for example, produce sharper, higher-intensity sounds due to less energy dissipation during motion, while increased chest wall thickness reduces audibility.[15][1]

Normal Heart Sounds

First Heart Sound

The first heart sound, denoted as S1, marks the onset of ventricular systole and is produced by the closure of the atrioventricular valves—the mitral valve on the left and the tricuspid valve on the right—as ventricular pressures exceed atrial pressures during isovolumetric contraction.[14][17] This sound coincides precisely with the QRS complex on the electrocardiogram (ECG), serving as a reliable auscultatory landmark for the start of mechanical systole in the cardiac cycle.[1] S1 comprises two primary components: the mitral closure (M1), which occurs first due to the more rapid pressure rise in the left ventricle, followed shortly by the tricuspid closure (T1).[14] The interval between M1 and T1 is typically about 0.04 seconds, reflecting the slight asynchrony in right and left ventricular contraction.[14] Normally, this brief separation results in a single, audible sound because the components are too closely timed for most listeners to distinguish without advanced phonocardiography.[14] In terms of acoustic properties, S1 is characterized by low-frequency vibrations (around 20–100 Hz) and a longer duration than the second heart sound (S2), often lasting 0.10–0.15 seconds, which gives it a duller, more prolonged quality compared to the sharper S2.[18] It is louder and more prominent when auscultated over left-sided areas, such as the cardiac apex (mitral area), where the mitral component predominates, whereas the tricuspid component is softer and best appreciated at the lower left sternal border.[18] The intensity of S1 varies physiologically based on factors influencing valve position and ventricular dynamics at the onset of systole. Increased intensity occurs with tachycardia or exercise, which shorten the PR interval and allow greater valve excursion before closure, as well as in mitral stenosis where the valve leaflets are held more open in diastole.[1] Conversely, decreased intensity is observed in conditions like heart failure (due to reduced contractility), obesity or emphysema (increasing the distance between heart and chest wall), or prolonged PR intervals that permit partial valve closure before systole.[1][19] Splitting of S1 is uncommon physiologically and typically perceived as a single sound, but pathologic widening of the M1-T1 interval can produce an audible split, most notably in right bundle branch block, which delays right ventricular contraction and thus T1.[14] Left bundle branch block may similarly affect timing but often renders S1 softer overall rather than distinctly split.[1]

Second Heart Sound

The second heart sound (S2) marks the end of ventricular systole and is primarily generated by the closure of the semilunar valves, specifically the aortic and pulmonic valves, which occurs shortly after the T wave on the electrocardiogram (ECG).[20] This sound signifies the transition to diastole, as the ventricles relax and the pressure in the great arteries exceeds ventricular pressure, causing the valve cusps to snap shut and vibrate the surrounding structures.[17] In the classic "lub-dub" rhythm of the heart, S2 corresponds to the "dub," contrasting with the first heart sound (S1) produced by atrioventricular valve closure at the onset of systole.[21] S2 consists of two main components: the aortic closure sound (A2), which is typically louder, higher-pitched, and earlier than the pulmonic closure sound (P2). A2 is generated by aortic valve closure and is best auscultated at the right upper sternal border, while P2 arises from pulmonic valve closure and is more prominent at the left upper sternal border.[20] Under normal conditions, these components produce physiologic splitting of S2, where the interval between A2 and P2 widens during inspiration due to delayed pulmonic valve closure from increased right ventricular stroke volume and prolonged ejection time.[21] This splitting narrows or becomes single during expiration. Compared to S1, S2 has a higher frequency spectrum and shorter duration, contributing to its sharper, more ringing quality.[17] The intensity of S2 can vary based on underlying hemodynamic conditions. A2 is often accentuated in systemic hypertension, reflecting increased aortic pressure that enhances valve closure force, while P2 may be louder in pulmonic stenosis due to heightened right ventricular pressure.[20] Conversely, A2 intensity diminishes in aortic regurgitation, as the regurgitant flow reduces the pressure gradient across the valve at closure.[17] Pathologic variations in S2 splitting provide diagnostic clues to cardiac abnormalities. Fixed splitting, where the A2-P2 interval remains constant regardless of respiration, is characteristic of atrial septal defect (ASD), resulting from persistent right ventricular volume overload that equalizes ejection times between ventricles.[22] Paradoxical splitting, in which the split widens during expiration and narrows on inspiration, occurs in conditions like left bundle branch block (LBBB), where delayed left ventricular contraction prolongs aortic ejection, causing A2 to follow P2.[23] These alterations in timing and intensity aid in identifying structural and conduction defects.[24]

Additional Heart Sounds

Third Heart Sound

The third heart sound (S3) is a low-frequency vibration that occurs in early diastole, immediately following the second heart sound (S2) and coinciding with the rapid filling phase of the ventricle.[3] This sound marks the transition from rapid to slowed ventricular filling, typically 0.12 to 0.18 seconds after the onset of the second heart sound in adults.[25] It can originate from either the left or right ventricle, though the left ventricular S3 is more commonly auscultated.[3] The mechanism of S3 production involves sudden deceleration of blood flow into the ventricle during early diastole, causing vibrations in the cardiohemic system (ventricular wall, blood, and surrounding structures).[25] This abrupt influx of blood, often due to elevated filling pressures, leads to the sound's characteristic low pitch, in the range of 10 to 50 Hz.[25] In physiological contexts, such as in children and young athletes, S3 reflects compliant ventricular walls accommodating normal rapid filling without pathology.[3] Clinically, an S3 in adults over 40 years often indicates ventricular dysfunction or volume overload, serving as an early marker of conditions like congestive heart failure, dilated cardiomyopathy, or severe mitral regurgitation. It is associated with reduced ejection fraction and restrictive filling patterns, contributing to a "ventricular gallop" rhythm when combined with S1 and S2. The presence of S3 correlates with adverse outcomes in heart failure patients, including higher hospitalization rates.[26] S3 is soft and low-pitched, requiring the bell of the stethoscope placed lightly at the cardiac apex, with the patient in the left lateral decubitus position to enhance detection.[3] Its intensity increases with maneuvers that boost venous return, such as lying supine or leg elevation, and it is typically absent in conditions like constrictive pericarditis due to restricted filling.[27] Differentiation from the fourth heart sound (S4) relies on timing—S3 occurs in early diastole during passive filling, while S4 arises in late diastole from atrial contraction—and patient demographics, as S3 is normal in youth but pathological in older adults, whereas S4 suggests atrial-ventricular dyssynchrony.[3]

Fourth Heart Sound

The fourth heart sound, denoted as S4, is a low-frequency diastolic sound that occurs in late diastole during atrial systole, immediately preceding the first heart sound (S1).[1] It arises from the atrial contraction, or "atrial kick," forcing blood into a ventricle with reduced compliance, generating vibrations in the ventricular wall and chordae tendineae.[1] This sound is typically absent in conditions like atrial fibrillation, where coordinated atrial contraction is lacking, preventing the presystolic filling that produces S4.[11] Physiologically, S4 reflects increased resistance to ventricular filling due to a stiff or non-compliant ventricle, often from conditions such as left ventricular hypertrophy.[28] It is best auscultated at the cardiac apex using the bell of the stethoscope in the left lateral decubitus position, as its low-frequency nature (around 20-30 Hz) requires light contact to avoid damping.[29] In tachycardia, S4 may merge with an S3 to form a "summation gallop," creating a single low-pitched sound during shortened diastole.[11] While generally considered pathologic in adults, S4 can occasionally be physiologic in highly trained athletes.[30] Clinically, an audible S4, often termed an "atrial gallop," signals diastolic dysfunction and is associated with systemic hypertension, ischemic heart disease, aortic stenosis, and hypertrophic cardiomyopathy.[4] It indicates pressure overload on the ventricle, as seen in active myocardial ischemia or heart failure with preserved ejection fraction, where treatment targets the underlying pathology rather than the sound itself.[28] The presence of S4 strengthens the diagnosis of these conditions, particularly when accompanied by a palpable presystolic apical impulse.[4]

Abnormal Heart Sounds

Heart Murmurs

Heart murmurs are abnormal, prolonged sounds generated by turbulent blood flow within the heart or great vessels, characterized as whooshing, swishing, or blowing noises audible via stethoscope.[5] These sounds arise from disruptions in normal laminar flow, such as high-velocity jets across narrowed valves or regurgitant streams through incompetent ones, distinguishing them from brief, discrete noises like clicks or snaps by their sustained duration.[6] Murmurs provide critical diagnostic clues to underlying cardiac pathology, though many are benign.[31] Classification of heart murmurs primarily relies on timing relative to the first heart sound (S1) and second heart sound (S2). Systolic murmurs occur during ventricular contraction, between S1 and S2, and are often ejection-type (midsystolic) or regurgitant (holosystolic); examples include the harsh, crescendo-decrescendo murmur of aortic stenosis radiating to the carotids or the high-pitched, blowing holosystolic murmur of mitral regurgitation heard at the apex.[32][6] Diastolic murmurs arise during ventricular relaxation, between S2 and the subsequent S1, and may be early (decrescendo, as in aortic regurgitation) or mid-diastolic (rumbling, as in mitral stenosis); they are generally rarer and more indicative of pathology.[32][33] Continuous murmurs extend through systole and diastole, often with systolic accentuation, such as the machinery-like murmur of patent ductus arteriosus connecting the aorta and pulmonary artery.[6][5] Etiologies of heart murmurs span structural, infectious, and physiologic categories. Valvular causes predominate in acquired disease, where rheumatic fever leads to scarring and fibrosis, resulting in stenosis (e.g., mitral or aortic) or regurgitation (e.g., mitral or tricuspid).[5][6] Congenital anomalies, present from birth, include septal defects like ventricular septal defect (VSD), which produces a holosystolic murmur from left-to-right shunting, or tetralogy of Fallot with associated pulmonic stenosis.[5][34] High-output states elevate flow across normal valves, generating innocent-like murmurs in conditions such as severe anemia (reducing blood viscosity) or thyrotoxicosis (increasing cardiac output).[34][6] Grading of heart murmurs employs the Levine scale, a 1-to-6 system based on auscultatory intensity, which correlates with severity in many cases but is subjective and influenced by examiner skill. Grade 1 is barely audible in a quiet room; grade 2 is soft but easily heard; grade 3 is moderately loud without thrill; grade 4 includes a palpable thrill; grade 5 requires the stethoscope edge for detection with thrill; and grade 6 is audible without the stethoscope with prominent thrill.[35][6] Beyond intensity, murmurs are characterized by timing (as noted above), location of maximal intensity (e.g., aortic area for stenosis), radiation (e.g., to axilla for mitral regurgitation), and pitch (high for regurgitation, low for stenosis).[6][11] Distinguishing innocent from pathologic murmurs is essential for clinical management. Innocent (functional or physiologic) murmurs occur in structurally normal hearts, often due to increased flow during growth, fever, pregnancy, or anemia, and are typically soft (grade 1-2), systolic, short, and without radiation or associated symptoms; they resolve spontaneously and require no intervention.[36][31] Pathologic murmurs, conversely, signal underlying defects like valvular disease or shunts, often louder (grade 3+), holosystolic or diastolic, with radiation, thrills, or abnormal S1/S2 splitting, and may accompany symptoms such as dyspnea or fatigue, necessitating echocardiography and potential treatment.[31][37]

Clicks, Snaps, and Rubs

Clicks, snaps, and rubs represent discrete, high-frequency abnormal heart sounds distinct from the prolonged turbulence of murmurs, arising from specific valvular, pericardial, or intracardiac abnormalities. These sounds are typically brief and sharp, aiding in the diagnosis of underlying cardiac pathologies when detected during auscultation. Ejection clicks are early systolic, high-pitched sounds occurring at the moment of maximal opening of the semilunar valves, often associated with valvular abnormalities such as bicuspid aortic valve or pulmonic stenosis.[38] These clicks are best heard at the base of the heart and may vary with respiration in pulmonic cases due to changes in valve excursion.[39] Midsystolic clicks, commonly linked to mitral valve prolapse, are sharp, high-frequency sounds originating from the sudden tensing of redundant mitral valve leaflets during systole.[40] They are typically auscultated at the cardiac apex and may precede a late systolic murmur, with timing influenced by maneuvers that alter left ventricular volume, such as standing or squatting.[40] Opening snaps are early diastolic, high-pitched sounds produced by the abrupt opening of a stenotic but mobile mitral valve in mitral stenosis, occurring shortly after the aortic component of the second heart sound.[41] The interval between the second heart sound and the snap inversely correlates with stenosis severity, and the sound is higher in pitch than a third heart sound, often heard best at the left sternal border.[42] Pericardial friction rubs are scratchy, triphasic sounds generated by the inflamed visceral and parietal pericardial layers rubbing together in acute pericarditis, with components corresponding to atrial systole, ventricular systole, and early diastole.[43] These rubs are independent of valvular events, typically auscultated over the left sternal border, and may intensify with inspiration or the patient leaning forward.[43] Tumor plops are rare, low-pitched early diastolic sounds resulting from the abrupt movement or prolapse of an intracardiac tumor, such as a left atrial myxoma, into the mitral orifice during ventricular filling.[44] They follow the second heart sound and can mimic an opening snap but are distinguished by echocardiography revealing the mobile mass.[45]

Auscultation Techniques

Surface Anatomy and Listening Positions

The auscultation of heart sounds relies on identifying specific surface anatomical landmarks where cardiac vibrations project most clearly to the chest wall. These auscultatory areas do not directly overlie the valves but correspond to regions of optimal sound transmission based on the heart's internal anatomy. The four classic areas are defined as follows: the aortic area at the second right intercostal space (ICS) adjacent to the sternum, the pulmonic area at the second left ICS adjacent to the sternum, the tricuspid area along the lower left sternal border (typically the fourth to fifth left ICS), and the mitral (apical) area at the fifth left ICS in the midclavicular line.[46][47] Selection of the stethoscope component enhances detection of different sound frequencies. The diaphragm is used for high-frequency components, such as the first heart sound (S1), second heart sound (S2), and systolic or diastolic murmurs, as it filters out lower frequencies for clearer auscultation. In contrast, the bell is applied with light pressure to capture low-frequency sounds, including the third heart sound (S3) and fourth heart sound (S4), which may otherwise be obscured.[1][48] Patient positioning optimizes proximity of the heart to the chest wall and minimizes interference from surrounding structures. The supine position, with the upper body elevated 30 to 45 degrees, facilitates auscultation of base sounds in the aortic and pulmonic areas. For enhanced detection at the apex, the left lateral decubitus position shifts the heart anteriorly and laterally, improving audibility of mitral and tricuspid sounds; this maneuver is particularly beneficial in obese patients, where subcutaneous adipose tissue can dampen acoustic transmission.[49][48] These listening positions reflect the anatomical orientations of the cardiac valves and great vessels, which result from embryologic cardiac looping that positions the outflow tracts superiorly and the atrioventricular valves more laterally within the mediastinum. For instance, S1 is most prominent at the mitral area due to its association with atrioventricular valve closure.[1]

Effects of Respiration and Maneuvers

Respiration significantly influences the intensity and timing of heart sounds and murmurs through changes in intrathoracic pressure and venous return. During inspiration, negative intrathoracic pressure enhances venous return to the right atrium, prolonging right ventricular ejection and delaying pulmonic valve closure (P2), which widens the physiological splitting of the second heart sound (S2).[20] This inspiratory increase in right-sided filling also augments the volume and flow across right-sided valves, thereby intensifying right-sided murmurs such as tricuspid regurgitation or pulmonic stenosis, while simultaneously reducing left-sided cardiac filling and diminishing the intensity of left-sided murmurs like mitral regurgitation.[50] In contrast, expiration reduces venous return to the right heart and increases left atrial filling, leading to earlier P2 and a narrowed or single-sounding S2 split.[20] Left heart sounds, including the first heart sound (S1) and left-sided murmurs, become more prominent during expiration due to enhanced left ventricular preload.[51] Physical maneuvers further modulate heart sounds by altering preload, afterload, or ventricular volumes, aiding in murmur characterization. The Valsalva maneuver, involving forced expiration against a closed glottis, decreases preload during its strain phase, softening most murmurs such as aortic stenosis or mitral regurgitation, but paradoxically intensifies the murmur of hypertrophic obstructive cardiomyopathy (HOCM) due to reduced left ventricular volume exacerbating dynamic outflow obstruction.[6] Similarly, in mitral valve prolapse (MVP), Valsalva brings the midsystolic click earlier and lengthens the subsequent murmur.[40] Isometric handgrip exercise increases systemic vascular resistance and afterload, which loudens regurgitant murmurs like mitral regurgitation, aortic regurgitation, and ventricular septal defect by widening the regurgitant orifice relative to forward flow, while decreasing the intensity of HOCM murmurs through increased left ventricular filling.[6] Squatting or passive leg raising abruptly increases venous return and preload, which delays the timing of the MVP click, shortens its associated murmur, and generally diminishes HOCM murmurs by enlarging the left ventricular cavity and reducing obstruction; conversely, these maneuvers may accentuate fixed obstructive murmurs like aortic stenosis.[6][50] These respiratory and maneuver-induced variations provide clinical utility in distinguishing innocent from pathologic murmurs; for instance, benign flow murmurs often diminish or vary markedly with positional changes and respiration, whereas pathologic murmurs like those in HOCM show characteristic directional responses that guide differential diagnosis.[52]

Diagnostic Recording

Phonocardiography

Phonocardiography is a non-invasive technique that graphically records the acoustic signals produced by the heart and great vessels, capturing them as waveforms using a sensitive microphone or transducer placed on the chest surface. The microphone detects vibrations from cardiac valve closures, blood flow turbulence, and myocardial contractions, converting them into electrical signals that are amplified and displayed on a recording device. These phonocardiograms (PCGs) are typically synchronized with an electrocardiogram (ECG) or carotid pulse tracing to precisely time the heart sounds relative to the cardiac cycle, facilitating accurate identification of events such as systole and diastole.[53][54] The development of phonocardiography began in the late 19th century with early mechanical devices for registering heart sounds, but it was refined in the early 20th century through innovations like Willem Einthoven's 1907 correlation of PCG tracings with ECG waves. Standardization advanced in the 1940s via the work of Samuel A. Levine, William Dock, and particularly Maurice B. Rappaport and Howard B. Sprague, who introduced multichannel recording systems that integrated PCG with ECG and other physiologic signals. Phonocardiography reached its peak in clinical use during the mid-20th century, serving as a key diagnostic tool for analyzing cardiac acoustics before the widespread adoption of echocardiography in the 1970s diminished its prominence.[55][56][57][58] In analysis, phonocardiography enables quantitative assessment of the first heart sound (S1), second heart sound (S2), third heart sound (S3), and fourth heart sound (S4) by measuring their timing within the cardiac cycle, relative intensity, and frequency content, often using filters to isolate low-frequency (20-100 Hz) components for S1-S4 and higher frequencies (100-600 Hz) for murmurs. It also quantifies splitting intervals, such as the A2-P2 split of S2, which normally measures 20-40 ms and widens in conditions like pulmonary hypertension. Murmurs are characterized by their duration, shape (e.g., crescendo-decrescendo), and timing (systolic or diastolic), providing objective data that correlates with auscultated primary sounds for enhanced diagnostic precision. Signal processing techniques, including time-frequency analysis, further delineate these features to detect abnormalities like prolonged splitting or extra sounds.[59][60][1] Key advantages of phonocardiography include its ability to provide an objective, visual representation of subtle or faint heart sounds that may elude traditional auscultation, allowing recordings to be replayed, archived, and shared for collaborative review. It operates effectively in noisy environments and reduces examination time through reliable, reproducible tracings. However, limitations persist, as it captures only superficial chest wall vibrations without spatial resolution to localize sound origins within the heart, and it is susceptible to artifacts from patient movement or respiration. Currently, phonocardiography serves primarily as an educational tool to train clinicians in recognizing heart sound patterns through visual-audio integration, improving diagnostic accuracy in novice learners by up to 20%. In resource-limited settings, low-cost digital implementations remain a valuable adjunct for basic cardiac assessment where advanced imaging is unavailable.[61][59][62][63]

Echocardiography and Advanced Imaging

Echocardiography serves as a cornerstone in correlating heart sounds with underlying cardiac structures, providing visual confirmation of valvular and myocardial dynamics that generate auscultatory findings. Transthoracic echocardiography (TTE), a non-invasive ultrasound modality, uses two-dimensional imaging and Doppler techniques to link sounds such as murmurs or extra heart sounds to specific abnormalities, including valve motion abnormalities and blood flow velocities across cardiac chambers. For instance, TTE can visualize mitral regurgitation jets corresponding to systolic murmurs or assess left ventricular filling patterns associated with third heart sounds (S3). This integration enhances diagnostic precision by temporally aligning acoustic events with real-time structural changes, often performed at the bedside to complement physical examination. Transesophageal echocardiography (TEE) offers superior resolution for detecting subtle structural issues that produce heart sounds, particularly in cases where TTE is limited by acoustic windows. By positioning the ultrasound probe in the esophagus, TEE provides high-fidelity images of posterior cardiac structures, making it ideal for identifying abnormalities like mitral valve prolapse that generate mid-systolic clicks or prosthetic valve dysfunction linked to murmurs. Clinical guidelines recommend TEE for intraoperative or high-risk assessments where precise etiology of sounds, such as rubs from pericardial effusion, requires detailed visualization. Its ability to capture high-resolution Doppler flows aids in quantifying severity, thereby guiding therapeutic decisions. Advanced imaging modalities extend beyond traditional echocardiography by incorporating digital and artificial intelligence (AI) tools to automate and enhance heart sound analysis. AI-assisted phonocardiography integrates machine learning algorithms with echocardiographic data to detect murmurs with sensitivities exceeding 90% in validation studies, outperforming manual auscultation in noisy environments. Wearable sensors, such as smartphone-based digital stethoscopes paired with ECG, enable remote monitoring of heart sounds and correlate them with echocardiogram-derived metrics for chronic conditions like heart failure. These devices facilitate continuous data collection, reducing the need for in-clinic visits. Building briefly on phonocardiographic tracings, these tools overlay acoustic waveforms onto imaging for multimodal interpretation. The integration of echocardiography with auscultation refines etiological diagnosis, as seen in cases where TTE or TEE visualizes mitral valve prolapse to explain characteristic clicks, allowing targeted interventions like surgical repair. Recent advances as of 2025 include machine learning models that improve detection sensitivity for S3 and S4 sounds in telehealth settings, achieving up to 95% accuracy by analyzing combined audio and imaging datasets from large cohorts.[64] These models, trained on diverse populations, enhance early identification of diastolic dysfunction, particularly in remote or underserved areas. Such innovations underscore the shift toward hybrid diagnostic platforms that merge acoustic and visual data for comprehensive cardiac evaluation.