Scanning probe microscopy (SPM) is a branch of microscopy that forms images of surfaces using a physical probe that scans the specimen. SPM was founded in 1981, with the invention of the scanning tunneling microscope, an instrument for imaging surfaces at the atomic level. The first successful scanning tunneling microscope experiment was done by Gerd Binnig and Heinrich Rohrer. The key to their success was using a feedback loop to regulate gap distance between the sample and the probe.[1]

Many scanning probe microscopes can image several interactions simultaneously. The manner of using these interactions to obtain an image is generally called a mode.

The resolution varies somewhat from technique to technique, but some probe techniques reach a rather impressive atomic resolution.[2] This is largely because piezoelectric actuators can execute motions with a precision and accuracy at the atomic level or better on electronic command. This family of techniques can be called "piezoelectric techniques". The other common denominator is that the data are typically obtained as a two-dimensional grid of data points, visualized in false color as a computer image.

Established types

[edit]

Image formation

[edit]

To form images, scanning probe microscopes raster scan the tip over the surface. At discrete points in the raster scan a value is recorded (which value depends on the type of SPM and the mode of operation, see below). These recorded values are displayed as a heat map to produce the final STM images, usually using a black and white or an orange color scale.

Constant interaction mode

[edit]

In constant interaction mode (often referred to as "in feedback"), a feedback loop is used to physically move the probe closer to or further from the surface (in the z axis) under study to maintain a constant interaction. This interaction depends on the type of SPM, for scanning tunneling microscopy the interaction is the tunnel current, for contact mode AFM or MFM it is the cantilever deflection, etc. The type of feedback loop used is usually a PI-loop, which is a PID-loop where the differential gain has been set to zero (as it amplifies noise). The z position of the tip (scanning plane is the xy-plane) is recorded periodically and displayed as a heat map. This is normally referred to as a topography image.

In this mode a second image, known as the ″error signal" or "error image" is also taken, which is a heat map of the interaction which was fed back on. Under perfect operation this image would be a blank at a constant value which was set on the feedback loop. Under real operation the image shows noise and often some indication of the surface structure. The user can use this image to edit the feedback gains to minimise features in the error signal.

If the gains are set incorrectly, many imaging artifacts are possible. If gains are too low features can appear smeared. If the gains are too high the feedback can become unstable and oscillate, producing striped features in the images which are not physical.

Constant height mode

[edit]

In constant height mode the probe is not moved in the z-axis during the raster scan. Instead the value of the interaction under study is recorded (i.e. the tunnel current for STM, or the cantilever oscillation amplitude for amplitude modulated non-contact AFM). This recorded information is displayed as a heat map, and is usually referred to as a constant height image.

Constant height imaging is much more difficult than constant interaction imaging as the probe is much more likely to crash into the sample surface.[38] Usually before performing constant height imaging one must image in constant interaction mode to check the surface has no large contaminants in the imaging region, to measure and correct for the sample tilt, and (especially for slow scans) to measure and correct for thermal drift of the sample. Piezoelectric creep can also be a problem, so the microscope often needs time to settle after large movements before constant height imaging can be performed.

Constant height imaging can be advantageous for eliminating the possibility of feedback artifacts.[39]

Probe tips

[edit]

The nature of an SPM probe tip depends entirely on the type of SPM being used. The combination of tip shape and topography of the sample make up a SPM image.[40][citation needed] However, certain characteristics are common to all, or at least most, SPMs.[citation needed]

Most importantly the probe must have a very sharp apex.[citation needed] The apex of the probe defines the resolution of the microscope, the sharper the probe the better the resolution. For atomic resolution imaging the probe must be terminated by a single atom.[41]

For many cantilever based SPMs (e.g. AFM and MFM), the entire cantilever and integrated probe are fabricated by acid [etching],[42] usually from silicon nitride. Conducting probes, needed for STM and SCM among others, are usually constructed from platinum/iridium wire for ambient operations, or tungsten for UHV operation. Other materials such as gold are sometimes used either for sample specific reasons or if the SPM is to be combined with other experiments such as TERS. Platinum/iridium (and other ambient) probes are normally cut using sharp wire cutters, the optimal method is to cut most of the way through the wire and then pull to snap the last of the wire, increasing the likelihood of a single atom termination. Tungsten wires are usually electrochemically etched, following this the oxide layer normally needs to be removed once the tip is in UHV conditions.

It is not uncommon for SPM probes (both purchased and "home-made") to not image with the desired resolution. This may occur if the tip is too blunt or if the probe has more than one apex, which can lead to doubled or ghost images. For some probes, in situ modification of the tip apex is possible, this is usually done by either crashing the tip into the surface or by applying a large electric field. The latter is achieved by applying a bias voltage (of order 10V) between the tip and the sample, as this distance is usually 1-3 Angstroms, a very large field is generated.

The additional attachment of a quantum dot to the tip apex of a conductive probe enables surface potential imaging with high lateral resolution, scanning quantum dot microscopy.

Advantages

[edit]

The resolution of these microscopes is not limited by diffraction but rather by the size of the probe-sample interaction volume (i.e., point spread function), which can be as small as a few picometres. Hence the ability to measure small local differences in object height (like that of 135 picometre steps on <100> silicon) is unparalleled. Laterally the probe-sample interaction extends only across the tip atom or atoms involved in the interaction.

The interaction can be used to modify the sample to create small structures (Scanning probe lithography).

Unlike electron microscope methods, specimens do not require a partial vacuum but can be observed in air at standard temperature and pressure or while submerged in a liquid reaction vessel.

Disadvantages

[edit]

The detailed shape of the scanning tip is sometimes difficult to determine. Its effect on the resulting data is particularly noticeable if the specimen varies greatly in height over lateral distances of 10 nm or less.

The scanning techniques are generally slower in acquiring images, due to the scanning process. As a result, efforts are being made to greatly improve the scanning rate. Like all scanning techniques, the embedding of spatial information into a time sequence opens the door to uncertainties in metrology, such as in measuring lateral spacings and angles, which arise due to time-domain effects like specimen drift, feedback loop oscillations, and mechanical vibrations.

The maximum image size is generally smaller.

Scanning probe microscopy is often not useful for examining buried solid-solid or liquid-liquid interfaces.

Scanning photo current microscopy

[edit]

Scanning photo current microscopy can be considered as a member of the Scanning Probe Microscopy (SPM) family. The difference between other SPM techniques and SPCM is, it exploits a focused laser beam as the local excitation source instead of a probe tip.[43]

Characterization and analysis of spatially resolved optical behavior of materials is very important in opto-electronic industry. Simply this involves studying how the properties of a material vary across its surface or bulk structure. Techniques that enable spatially resolved optoelectronic measurements provide valuable insights for the enhancement of optical performance. Scanning photo electron microscopy has emerged as a powerful technique which can investigate spatially resolved optoelectronic properties in semiconductor nano structures.

Principle

[edit]
Laser scan of the scanning photocurrent microscope

In scanning photo current microscopy, a focused laser beam is used to excite the semiconducting material producing excitons (electro-hole pairs). These excitons undergo different mechanisms and if they can reach the nearby electrodes before the recombination takes place a photocurrent is generated. This photocurrent is position dependent as it, raster scans the device.

Scanning photo current microscopy analysis

[edit]

Using the position dependent photocurrent map, important photocurrent dynamics can be analyzed.

Scanning photocurrent microscopy provides information on carrier transport, such as minority carrier diffusion length and recombination dynamics, as well as on local doping concentration and built-in electric fields.

Visualization and analysis software

[edit]

In all instances and contrary to optical microscopes, rendering software is necessary to produce images. Such software is produced and embedded by instrument manufacturers but also available as an accessory from specialized work groups or companies. The main packages used are freeware: Gwyddion, WSxM (developed by Nanotec) and commercial: SPIP (developed by Image Metrology), FemtoScan Online (developed by Advanced Technologies Center), MountainsMap SPM (developed by Digital Surf), TopoStitch (developed by Image Metrology).

References

[edit]

Further reading

[edit]
[edit]
Revisions and contributorsEdit on WikipediaRead on Wikipedia
from Grokipedia
Scanning probe microscopy (SPM) is a family of techniques that use a sharp physical probe to scan the surface of a sample, measuring interactions such as forces, currents, or fields to generate high-resolution images and maps of surface properties at the nanoscale or even atomic level. These methods enable the study of , electronic structure, mechanical properties, and chemical composition without requiring a or specific sample preparation, distinguishing them from traditional electron microscopy. The foundational technique, scanning tunneling microscopy (STM), was invented in 1981 by and at IBM's Research Laboratory, utilizing quantum tunneling of electrons between a conductive probe tip and sample to achieve atomic resolution on conductive surfaces. This breakthrough earned Binnig and Rohrer the 1986 , shared with for electron microscopy advancements. Building on STM, (AFM) was developed in 1986 by Binnig, Christoph Gerber, and Calvin Quate, extending SPM capabilities to non-conductive samples by detecting van der Waals forces or other interactions via a cantilever-mounted tip. Subsequent variants, such as magnetic force microscopy (MFM) and scanning near-field optical microscopy (SNOM), have expanded SPM to probe magnetic, optical, and other properties. SPM techniques have revolutionized nanoscience and nanotechnology, enabling applications in materials characterization, biological imaging (e.g., DNA and proteins), semiconductor device development, and surface manipulation for nanofabrication. Modern instruments operate in diverse environments, from ambient air to ultra-high vacuum and cryogenic temperatures down to millikelvin levels, achieving resolutions better than 0.1 nm laterally and providing spectroscopic data on local material properties. As of 2025, ongoing advancements, including hybrid systems combining SPM with other spectroscopies, AI-driven autonomous operation, and high-speed imaging techniques, continue to push the boundaries of precision measurement and quantum material studies.

Overview and History

Definition and Principles

Scanning probe microscopy (SPM) encompasses a family of techniques that employ a sharp physical probe to scan a sample's surface, detecting local interactions to generate high-resolution maps of topography, electronic properties, or other surface characteristics at atomic or molecular scales. These methods enable nanoscale and manipulation by exploiting interactions that are highly sensitive to the probe-sample separation, typically on the order of nanometers. The fundamental principles of SPM revolve around measuring localized probe-sample interactions, such as quantum mechanical tunneling currents or van der Waals forces, which decay rapidly with distance and provide exquisite sensitivity to surface features. The probe is systematically raster scanned across the sample in a grid-like pattern using piezoelectric actuators for precise, incremental movements, allowing point-by-point data collection to reconstruct the surface profile. A critical feedback loop continuously monitors the interaction signal—such as current or force—and adjusts the probe's vertical position to maintain a setpoint, ensuring stable and compensating for surface variations. SPM achieves resolutions down to the atomic level, with typical lateral resolutions of 0.1–10 nm and vertical resolutions of 0.01–1 nm, limited primarily by probe geometry and interaction range. In , a prominent SPM variant, the tip-sample force arises as the negative gradient of the interaction , expressed as
F=dUdr,F = -\frac{dU}{dr},
where U(r)U(r) is the potential energy and rr is the separation distance; this force deflects the supporting according to , F=kzF = -kz, with kk as the spring constant and zz as deflection—equating these relations quantifies the interaction from measurable cantilever response.

Historical Development

The origins of scanning probe microscopy (SPM) trace back to the invention of the (STM) in 1981 by and at IBM's Research Laboratory. This breakthrough instrument enabled atomic-scale imaging of conductive surfaces by measuring quantum tunneling currents between a sharp probe tip and the sample, overcoming the diffraction limits of conventional optical microscopy. Their work, detailed in early publications and recognized with the 1986 shared with , laid the foundational principles for SPM techniques. Building on STM's success, the field expanded rapidly in the mid-1980s to address limitations with non-conductive materials. In 1986, Binnig, along with Calvin F. Quate and Christoph Gerber, developed the atomic force microscope (AFM), which detects van der Waals forces between a probe and sample surface, allowing high-resolution imaging of insulators and biological specimens. This innovation, published in , marked a pivotal by broadening SPM's applicability beyond conductive samples. Quate's contributions were instrumental in advancing probe-based sensing, and he continued influencing the field until his death in 2019. Commercialization accelerated in the late 1980s and 1990s, with Digital Instruments introducing the first commercial AFM in 1989, followed by companies like Park Systems and Instruments (via its 1998 acquisition of Digital Instruments) introducing widely adopted systems, making SPM accessible for industrial and academic research. The 2000s saw the proliferation of SPM variants, including magnetic force microscopy (MFM) introduced in 1987 by Y. Martin and H. K. Wickramasinghe to map magnetic domains on surfaces, and scanning near-field optical microscopy (SNOM), which combined SPM with optical near-field probing for sub-wavelength resolution imaging, with practical implementations emerging in the early 1990s. These developments enhanced SPM's versatility for studying magnetic and optical properties at the nanoscale. In the 2020s, advancements have pushed boundaries further, with claims of sub-atomic resolution in non-contact AFM for visualizing chemical bonds and molecular orbitals reported in publications since 2020. Integration of artificial intelligence for image enhancement and noise reduction in SPM data processing has become prominent post-2020, improving accuracy in topography and spectroscopy analyses. Hybrid SPM-optical systems, such as advanced SNOM variants, have evolved by 2025 to enable high-order near-field imaging of low-dimensional materials. Ongoing research in cryogenic SPM (cryo-SPM), often conducted at millikelvin temperatures using specialized systems, has focused on quantum materials, revealing nanoscale phenomena in correlated electron systems.

Types of Scanning Probe Microscopes

Scanning Tunneling Microscopy

Scanning tunneling microscopy (STM) is a pivotal technique in scanning probe microscopy that enables atomic-scale imaging and manipulation of material surfaces by exploiting quantum mechanical tunneling of electrons. Developed in 1981 by and at Zurich, STM involves a sharp metallic probe tip positioned in close proximity (typically 0.4–1 nm) to a conductive sample surface, where a bias voltage induces a tunneling current between them. This current arises from the overlap of the tip's and sample's electron wavefunctions across the vacuum gap, providing exquisite sensitivity to surface and electronic properties. The technique requires electrically conductive samples, as the tunneling process depends on the delocalized electrons in metals or semiconductors, limiting its application to insulating materials. STM achieves lateral resolutions on the order of 0.1 nm, allowing visualization of individual atoms and lattice structures. The core principle of STM rests on the exponential dependence of the tunneling current on the tip-sample separation, derived from approximations to the time-independent for a one-dimensional potential barrier. In the simplest model, the current II is approximated as II0exp(2κd)I \approx I_0 \exp(-2 \kappa d), where I0I_0 is a prefactor related to the applied bias and material properties, dd is the tip-sample distance, and κ=2mϕ/\kappa = \sqrt{2m \phi}/\hbar
Add your contribution
Related Hubs
User Avatar
No comments yet.